Relay Power Supply Module MAIN - PS978
J7 - Blower, Convection Fan, Door Lock Motor
J10 - Cabinet Ground
J11 - Neutral
J14 - L1
J15 - Communications
J16 - Lock Switches
J17 - Communications
J20 - L1 and L2
J21 - Neutral
K1 - Convection Fan Motor Direction
K3 - Lower Broil, Lower Bake, and Convection
K4 - Both Oven Lights
K5 - Blower
K7 - Lower Bake and Convection Elements
K8 -
Convection Fan Motor Power
K10 - Convection Element
K11 - Not Used
K13 - Upper Door Lock Motor
K14 - Double Line Break for Lower Bake,
(Upper), Oven Lights, Door Switches
Elements
Lower Broil, Convection, and Lower Broil
Boost Elements.
J7
J14
J21
K1
K4
K5
K8
K11
K13
K3
K7
K10
K14
J10
J11
J16
J17
J15
J20
Relay Jumper Wire