– 22 –
To remove the inner door assembly:
1. Remove the door. See previous page.
2. Place the door assembly, gasket side up, on a
protective surface.
3. On PHS925, remove the three 1/4-in. hex-head
screws from the bottom of the door assembly.
5. On PHS925 remove the 2 Phillips-head screws
from the top of the inner door assembly.
To replace the inner door assembly:
1. Remove the inner door assembly. (See To
remove the inner door assembly, this section.)
2. Remove the T-20 Torx screws (3 on each side
PHS925, 2 on each side PS978), that attach each
door hinge to the inner door. Carefully turn the
door over and remove both door hinges.
3. Remove the six 1/4-in. hex-head screws that
attach the inner window glass assembly to the
heat barrier.
(Continued next page)
Note: When installing the inner door assembly, rst
capture each top screw using the retainer/spacer.
Retainer/Spacer
Screw
4. On PS978, remove the four T-20 Torx screws
from the bottom of the door assembly.
Note: The inner door assembly is heavier than the
outer door assembly.
6. Separate the inner door assembly from the
outer door assembly.
Omitted on
PS978