– 40 –
3-Way Valve
The 3-way valve is located beneath the main control
board in the machine compartment and is accessed
from the back of the refrigerator. It is composed of a
magnetic coil and a valve body. Two ¼-in. hex-head
screws mount the valve to the cabinet.
Make certain that rubber gaskets are installed
on mounting bracket to reduce vibration.
Capillary Tube to Fresh
Food
Jumper Tube to Drier
Capillary Tube to
Freezer
Coil
Valve Body
Three copper tubes connect to the 3-way valve.
One jumper tube connects from the drier to the
inlet on the valve.
A freezer capillary and a fresh food capillary
connect to the other two tubes on the valve.
Rubber Gaskets
3-Way Valve Coil
The 3-way valve coil receives 12-VDC pulses from
the main board to change the position of the valve.
The pulses come too quickly to measure with a volt
meter.
The 3-way valve coil has a resistance value of
approximately 46 ohms that can be measured
between the coil pins.
(Continued next page)