Loading...
– 52 –
J10
J5
K2
K1
K3
K4
Main Control Board
J4 or J16
J3 or J10
J1 or J14
J2 OR J13
J7
J4
J3
J1
J14
J2
J12
K5
J13
J11
J8
J9
Some of the low-voltage DC
connector labeling on this model
may differ from other models.
The function and diagnostics for
these connectors are identical for
all models.
J10 and J13 - Earth (Ground)
J8 - Line (L1) to AC Compressor*
J9 - Defrost Heater
J11 - Line (L1)
J7 - Neutral, Door Switches, CustomCool Heater,
Water Valve, Cube Solenoid, Auger Motor
J12 - Duct Heater
K1 - Auger
K2 - Crusher
K3 - Water
K4 - Defrost
K5 - CustomCool
J4 - LCD Board
J3 - QuickFreeze Fan, Beverage Center Fan, 3-way
Valve
J1 - Fresh Food Thermistor, Freezer Thermistor, Fresh
Food Evaporator Thermistor, Freezer
Evaporator Thermistor, Model Selector
J14 - Flow Meter
J15 - Inverter**
J2 - Fan Common, Evaporator Fan, Condenser Fan,
Fresh Food Fan, CustomCool Fan, Model Selector
J5 - CustomCool Damper(s), CustomCool Thermistor
J15
Control Board Connector Locator
* Single-speed compressors only
** 3-speed compressors only
(Continued next page)