– 56 –
CONTROL BOARD PIN DEFINITIONS
CONNECTOR PIN INPUT OUTPUT FUNCTION
J7 1 VAC Switched L1 voltage to the auger motor - 120 VAC.
J7 2 VAC Switched L1 voltage to the cube solenoid - 120 VAC.
J7 3 VAC Switched L1 voltage to the water valve - 120 VAC.
J7 4 VAC Receives L1 input from freezer door switch when freezer door is
closed.
J7 5 VAC Switched L1 voltage to the ExpressThaw (CustomCool™) heater
- 120 VAC.
J7 6 VAC Receives L1 input from fresh food door switch when door is open.
This input is used for evaporator fan control, liner protection
mode calculations, door alarm calculations, and adaptive defrost
calculations.
J7 7 VAC Receives L1 input from freezer door switch when door is open.
This input is used for evaporator fan control, liner protection mode
calculations, door alarm calculations, adaptive defrost calculations
and some door interlock functions. Switch must be closed in door
closed position (switch depressed) for dispenser LED light and duct
door magnet to energize.
J7 9 VAC AC neutral in.
CONTROL BOARD PIN DEFINITIONS
CONNECTOR PIN INPUT OUTPUT FUNCTION
J8 1 VAC Switched L1 voltage to the compressor - 120 VAC. (Only used on
single-speed compressor models.)
(Continued next page)
CONTROL BOARD PIN DEFINITIONSS
CONNECTOR PIN INPUT OUTPUT FUNCTION
J5 1 VDC VDC ExpressChill (CustomCool™) damper.
J5 2 VDC VDC ExpressChill (CustomCool™) damper.
J5 3 VDC VDC ExpressChill (CustomCool™) damper.
J5 4 VDC VDC ExpressChill (CustomCool™) damper.
J5 5 VDC Provides 5 VDC for ExpressChill (CustomCool™) thermistor.
J5 6 VDC Feedback of ExpressChill™ (CustomCool™) thermistor. Thermistor is
NTC (when temperature drops, resistance value increases), causing
return voltage reduction.