Installation Instructions
WASHER LOCATION
The washer must be installed on firm flooring to
minimize vibration during the spin cgcle.
Concrete flooring is best, but a wood floor is
sufficient, provided floor support meets FHA
standards. The washer should not be installed
on rugs or exposed to weather.
Minimum clearance between washer and adjacent
walls or other surfaces:
, 1" either side
2" front
4" rear
Minimum vertical space from floor to overhead
shelves, cabinets, ceilings, etc., is 58".
WASHER DIMENSIONS
Front View
27"
-,_qm.m
(68.6 cm)
]
45½"
(114.6 cm)
--'lb--
Side View
28½"
(73.3 cm)
57½"
(145.1 cm)
(with lid
open)
J
REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
Your washer is approved for installation in an
alcove or closet, as stated on a label on the back
of the machine.
Minimum clearance between washer and adjacent
walls or other surfaces:
, 1" either side
, 2" front
, 4" rear
Minimum vertical space from floor to overhead
shelves, cabinets, ceilings, etc., is 58".
Closet doors must be Iouvered or otherwise
ventilated and have at least 60 square inches of
open area for washer onlg, or if the closet contains
both a washer and a drger, door must contain at
least 120 square inches of open area equallg
distributed. Air openings are required to be
unobstructed when a door is installed. A Iouvered
door with equivalent air openings for the full length
of the door is acceptable.
NOTE: The clearances stated on this label
are minimums. Consideration must be given to
providing adequate clearances for installing and
servicing.