B-22 T35 Transformer Protection System GE Multilin
B.4 MEMORY MAPPING APPENDIX B
B
3A34 ...Repeated for Field Contact Input 29
3A3F ...Repeated for Field Contact Input 30
3A4A ...Repeated for Field Contact Input 31
3A55 ...Repeated for Field Contact Input 32
3A60 ...Repeated for Field Contact Input 33
3A6B ...Repeated for Field Contact Input 34
3A76 ...Repeated for Field Contact Input 35
3A81 ...Repeated for Field Contact Input 36
3A8C ...Repeated for Field Contact Input 37
3A97 ...Repeated for Field Contact Input 38
3AA2 ...Repeated for Field Contact Input 39
3AAD ...Repeated for Field Contact Input 40
Field Unit Shared Inputs (Read/Write Setting) (16 modules)
3B00 Field Shared Input 1 ID 0 to 65535 --- 1 F205 "SI 1"
3B06 Field Shared Input 1 Unit Origin 1 0 to 8 --- 1 F256 0 (None)
3B07 Field Shared Input 1 Channel Origin 1 1 to 15 --- 1 F001 1
3B08 Field Shared Input 1 Events 0 to 1 --- 1 F102 1 (Enabled)
3B09 ...Repeated for Field Shared Input 2
3B12 ...Repeated for Field Shared Input 3
3B1B ...Repeated for Field Shared Input 4
3B24 ...Repeated for Field Shared Input 5
3B2D ...Repeated for Field Shared Input 6
3B36 ...Repeated for Field Shared Input 7
3B3F ...Repeated for Field Shared Input 8
3B48 ...Repeated for Field Shared Input 9
3B51 ...Repeated for Field Shared Input 10
3B5A ...Repeated for Field Shared Input 11
3B63 ...Repeated for Field Shared Input 12
3B6C ...Repeated for Field Shared Input 13
3B75 ...Repeated for Field Shared Input 14
3B7E ...Repeated for Field Shared Input 15
3B87 ...Repeated for Field Shared Input 16
Field Unit Contact Outputs (Read/Write Setting) (8 modules)
3B90 Field Contact Output 1 ID (6 items) --- --- --- F205 "FCO U /OUT"
3BB4 Field Output 1 Operate (6 items) 0 to 4294967295 --- 1 F300 0
3BC0 Field Output 1 Seal In (6 items) 0 to 4294967295 --- 1 F300 0
3BCC Field Output 1 Events (6 items) 0 to 1 --- 1 F102 1 (Enabled)
3BD2 ...Repeated for Field Contact Output 2
3C14 ...Repeated for Field Contact Output 3
3C56 ...Repeated for Field Contact Output 4
3C98 ...Repeated for Field Contact Output 5
3CDA ...Repeated for Field Contact Output 6
3D1C ...Repeated for Field Contact Output 7
3D5E ...Repeated for Field Contact Output 8
Field Unit Latching Outputs (Read/Write Setting) (8 modules)
3DC7 Field Latching Output 1 ID 0 to 1 --- 1 F205 "FLO Ux /LO"
3DCD Field Latching Output 1 Open 0 to 4294967295 --- 1 F300 0
3DCF Field Latching Output 1 Close 0 to 4294967295 --- 1 F300 0
3DD1 Field Latching Output 1 Events 0 to 1 --- 1 F102 1 (Enabled)
3DD2 Field Latching Output 1 Reserved (2 items) 0 to 1 --- 1 F001 0
3DD4 ...Repeated for Field Latching Output 2
3DE1 ...Repeated for Field Latching Output 3
3DEE ...Repeated for Field Latching Output 4
3DFB ...Repeated for Field Latching Output 5
Table B–10: MODBUS MEMORY MAP (Sheet 14 of 52)
ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT