APPENDIX D: MISCELLANEOUS REVISION HISTORY
T35 TRANSFORMER PROTECTION SYSTEM – INSTRUCTION MANUAL D-3
D
Table D-3: Major changes for T35 manual version AE3 (English)
Table D-4: Major changes for T35 manual version AE1 (English)
Table D-5: Major changes for T35 manual version AC1 (English)
--- Updated Contact Inputs from 96 to 120 and Contact Outputs from 64 to 72 in Product Description in chapter 2 and FlexLogic
operands table in chapter 5
3-36 Updated RS422 and Fiber Interface Connection figure for the clock channels (from 7a and 7b to 1a and 1b)
3-67 Added Connect to a D400 Gateway section
4-43 Updated LED Labelling instructions for the new Front Panel Label Designer
4-50 Added Standard Front Panel section for labelling LEDs and pushbuttons
5-106 Added USB Port section to enable/disable the USB port on the graphical front panel
5-120 Updated User-programmable Pushbuttons section as per specifications
5-154 Updated Breakers section as per specifications
5-159 Updated Disconnect Switches section as per specifications
9- Added Theory of Operation chapter in order to add Saturation Detector section
10-5 Added Convert Device Settings section
10-7 Added Copy Settings to Other Device section
10-15 Added Replace Front Panel section for retrofit with the new graphical front panel
Page Description
--- General revision
2- Updated order codes
9- Added Theory of Operation chapter in order to add Saturation Detector section
10-5 Added Copy Settings to Other Device section
Page Description
--- General revision
--- Added routable GOOSE content in chapters 2 and 5
3-36 Updated RS422 and Fiber Interface Connection figure for the clock channels (from 7a and 7b to 1a and 1b)
4- Added Engineer content
5- Updated IEC 61850 content
A- Updated FlexAnalog table for most UR products
Page Description
--- General revision. Added online help and updated generic online help.
--- Deleted EAC logo from title page and deleted EAC certification from Approvals specifications because document not
translated into Russian
--- Updated Breaker Arcing Current content, including FlexLogic operands table, settings, logic diagram, actual values, Modbus
memory map
--- Updated transformer Percent Differential element (for CT Saturation) to include 1-out-of-3, including in specifications,
FlexLogic operands, settings, and logic diagram
--- Added Restricted Ground Fault element to description, specifications, FlexLogic operand table, settings, actual values,
FlexAnalog table, Features per Product table, Modbus memory map, IMD table
--- Added Transformer Thermal Inputs content to settings, actual values, features per product table, Modbus memory map, IMD
tables
--- Added Phase Instantaneous Overcurrent (IOC) content to description, specifications, FlexLogic operand table, settings,
features per product table, Modbus memory map, IMD tables
--- Added Ground Instantaneous Overcurrent (IOC) content to description, specifications, FlexLogic operand table, settings,
features per product table, Modbus memory map, IMD tables
--- Added Transformer Hottest-Spot temperature, Transformer Aging Factor, Transformer Loss of Life content to description,
specifications, FlexLogic operands table, actual values, FlexAnalog table, Modbus memory map, IMD tables