• Supports Tetra miniMAX, Tetra MAX, Tetra PowerMAX,
Tetra PowerStrip and Tetra miniStrip LED lighting systems
• Class 2 wiring per NEC Article 725 (SELV)
• IP66 rated: wet location rated
• M20 Thread
(GEPS12W-60M)
Tetra
®
LED Systems Power Supply
12
Volt
GE
Lighting Solutions
Installation Guide
imagination at work
Power Supply Features
Power Supply Installation
1
Power supply
Conduit
Power supply
input wires
AC Line
Run AC line through conduit and
attach conduit to outdoor-rated
enclosure. Attach power supply to
enclosure.
3
Brown (-)
Blue (+)
Connect the AC line to the brown
(line) and blue (neutral) input wires of
the power supply using 18-14 AWG
(0.82-2.08 mm
2
) twist-on wire
connectors. Properly ground (green
wire with yellow stripe) power supply
in accordance with National Electric
Code (NEC) Article 600.
Connect the red stripe wire (+) of the
LED strip to the red wire (+) of the
power supply. Connect the white
wire (-) of the LED strip to the black
wire (-) of the power supply.
2
To power supply
Red (+)
Red stripe (+)
White (-)
Black (-)
NOTE: All electrical connections
should be made within the letter.
RISK OF ELECTRIC SHOCK:
• Disconnect power at fuse box or circuit breaker before servicing or
installing product.
• Properly ground Tetra
®
power supply.
RISK OF FIRE:
• Use only approved wire for input/output connection.
Minimum size 18 AWG (0.82 mm
2
)
• Follow all local codes.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au
disjoncteur avant l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation
électrique Tetra
®
.
RISQUES D’INCENDIE
• N’utilisez que des ls approuvés pour les entrées/sorties de
connexion. Taille minimum 18 AWG (0.82 mm
2
).
• Respectez tous les codes locaux.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
Green with
yellow stripe
Question and Answer IconNeed help?

Do you have a question about the GE Tetra Series and is the answer not in the manual?

GE Tetra Series Specifications

General IconGeneral
Storage Temperature-40°C to +85°C
DimensionsVaries by model
WeightVaries by model
Protection FeaturesOver Temperature Protection
Cooling MethodConvection
CertificationsCE, RoHS
Output Voltage12 VDC or 24 VDC (depending on model)
Operating Temperature-40°C to +60°C

Summary

Tetra LED Systems Power Supply Installation Guide

Power Supply Features Overview

Lists key features including supported systems, certifications, and ratings.

Important Safety Instructions

Crucial safety warnings regarding electrical shock and fire hazards before installation.

Power Supply Installation Steps

Step-by-step guide for physically installing the power supply unit.

Power Supply Specifications and Performance

Performance Data Details

Details input voltage, frequency, current, output, and environmental operating parameters.

Remote Mounting Distance Specifications

Specifies maximum mounting distances for different wire gauges and Tetra products.