– 36 –
To remove the pump:
Remove the service panel.
Caution: Under normal conditions, approximately 
1 quart of water will drain out when the pump 
cleanout is removed. 
Place a shallow pan under the drain cleanout.
Turn the pump cleanout counterclockwise 
approximately 2 turns, then pull outward.
1.
2.
3.
Strainer
Note: Remove any debris or foreign objects from the 
strainer and interior of the pump before reinstalling.
 Remove the drain hoses from the pump:
Note: The drain hoses are diffi cult to remove. 
Squeeze each clamp and slide it back.
Carefully break each hose loose by inserting 
a small fl at-blade screwdriver under the 
hose to break the seal.
Remove the tub outlet hose from the pump 
inlet.
Remove the drain hose from the pump 
outlet.
4.
a.
b.
c.
d.
Disconnect the 2 wires from the pump.5.
Remove the 2 Phillips-head screws that hold the 
pump to the chassis. 
Pull the pump rearward to clear the 2 locator 
pins from the 2 grommets in the front frame.
6.
7.
Drain Hose
Tub 
Outlet 
Hose
Pump 
Wires
Remove the pump thru the enlarged opening on 
the left side of the front frame.
8.
Locator Pins