– 54 –
Error Code Description Problem Possible Cause/Action
E43
DC Fault -
Inverter
Inverter failure.
Non-recoverable error.
Replace inverter control board.
•
•
E45 Drive motor - 
overload current
Load too 
heavy. 
Check Motor - t10 tumble, t11 spin, T14 spin.
Check mechanical faults - check belt, basket, 
bearing - rotate basket by hand.
Power down (unplug) washer, wait 30 seconds and 
retry - if reoccurs, replace inverter. (Note: Cannot 
occur with open winding.)
•
•
•
E46 Drive motor -  
over temperature
Inverter over 
temperature.
Check Motor - t10 tumble, t11 spin, T14 spin.
Power down (unplug) washer, wait 30 seconds and 
retry -  use whites cycle sanitize temperature - if 
reoccurs, replace drive motor. (Note: Cannot occur 
with open winding.)
•
•
E47 Heat sink - over 
temperature
Inverter over 
temperature. 
Check Motor - t10 tumble, t11 spin, T14 spin.
Power down (unplug) washer, wait 30 seconds and 
retry -  use whites cycle sanitize temperature - if 
reoccurs, replace drive motor. (Note: Cannot occur 
with open winding.)
•
•
E48 Drive motor 
- open
Open motor 
phase.
Check Motor - t10 tumble, t11 spin, T14 spin.
Check motor for open winding - if OK, replace 
inverter.  (Note: Occurs with open winding.)
•
•
E49 Drive motor - 
overload power
Load too 
heavy.
Check Motor - t10 tumble, t11 spin, T14 spin.
Check mechanical faults (binding) - belt, basket, 
bearing - rotate basket by hand.
Check motor for shorted winding - if OK, replace 
inverter.
Power down (unplug) washer, wait 30 seconds and 
retry - if reoccurs, replace inverter. (Note: Cannot 
occur with open winding.
•
•
•
•
E4A Under volts Under volts - 
DC bus voltage 
(inverter).
Check Motor - t10 tumble, t11 spin, T14 spin.
Power down (unplug) washer, wait 30 seconds and 
retry - if reoccurs, replace inverter. (Note: Cannot 
occur with open winding.)
•
•
E4B Power up 
problems
Software/
hardware 
problems.
Check Motor - t10 tumble, t11 spin, T14 spin.
Check motor windings - internal short
Power down (unplug) washer, wait 30 seconds and 
retry - if reoccurs, replace inverter. (Note: Cannot 
occur with open winding.)
•
•
•
E4C Over volts Over volts - DC 
bus (inverter).
Check Motor - t10 tumble, t11 spin, t14 spin.
Power down (unplug) washer, wait 30 seconds and 
retry - if reoccurs, replace inverter. (Note: Cannot 
occur with open winding.)
•
•