Tub should stop spinning 7 seconds after lid is lifted.
If the tub takes approximately 10 seconds to stop, check drive belt for wear.
If tub coasts to stop, brake resistor has failed and inverter/motor assembly must be replaced.
If the tub takes longer than 25 seconds to stop, the inverter will initiate a brake resistor error code. (See
Inverter/Motor Error Codes.)