– 24 –
6. Lift the water valve and dispenser box assembly
up to clear the top cover and move toward the
back of the washer.
7. Remove the one Philips head screw that secures
the water valve to the dispenser box to separate
them.
Diagnosing the Water Valve
If no water is coming out of the valve, check the
inlet hoses and water valve screens to make
sure they are not clogged.
If water is still not coming out of the valve, put
the control into Service mode and apply voltage
to the water valve coil that is not working. Check
for 120 VAC at the board or the valves. Check
from the common Neutral (blue) wire to the
orange wire for the HOT water coil. And from
the blue Neutral wire to the gray wire for the
COLD water coil.
The resistance of the coil can be checked at
those same connectors. The resistance should
read approximately 1.2k ohms (1200 ohms).