EasyManua.ls Logo

GEA FK40 Series - Page 4

GEA FK40 Series
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
09665-12.2014-Gb
2 I Safety
General safety instructions
DANGER Risk of electric shock
Before you carry out any repair work, disconnect the compressor from the electricity network
Turn the main switch to "O" (OFF)
Secure the main switch against an unauthorised restart
WARNING Refrigerating compressors are pressurised machines and therefore require particular
caution and care in handling.
Only qualied personnel are allowed to perform any work on refrigeration compressors.
The national safety regulations, accident prevention regulations, technical rules and specic
regulations (EN 378 and others) must be taken into account absolutely.
Never put the safety switch out of action!
Prior to commissioning, check whether all the components installed by the user have been
fastened expertly and connected pressure-tight with the compressor (e.g. piping, plugs, union
nuts, replaced components etc.).
Before commissioning, evacuate the refrigerant systems carefully including the compressor and
afterwards charge refrigerant.
Prior to starting the compressor open discharge shut-off valve and suction shut-off valve.
Do not start the compressor in vacuum. Operate the compressor only when the system is charged.
Risk of burns! Depending on the operating conditions, surface temperatures of over 60 °C
on the pressure side or below 0 °C on the suction side can be reached.
The maximum permissible overpressure must not be exceeded, even for testing purposes.
Danger of injury! Never grab rotating parts during operation!