Maintenance
Service intervals
Practically no maintenance is required. However, for an optimal operating safety and service life of the compressor we recommend to
carry out the necessary maintenance work regularly according to the specications of the manufacturer of the refrigerating plant.
5 I Maintenance
Function checks to be carried out once a year
Leak test of the plant
Checking the running noise of compressor
Checking pressures and temperatures of the plant
Checking the tensioner for orderly seating
Checking the V belts for tension and condition
Checking the oil level in the crankcase
Checking the xing screws for tightening
Checking the function of the ancillary units
Checking the electrical connections for clean, rmly xed contacts and the leads for chang points
Oil level check
After starting the compressor, the oil level has to be checked. For this:
The driving engine should be in the „High idle“ operating condition (elevated idling speed)
Compressor running time at least 10 min.
The plant should have reached the operating point
The oil level must be visible in the sight glass
Changing oil
In case of orderly manufactured and operated plants an oil change is in principle not absolutely necessary.
Yet, based on decades-long experience we recommend to carry out the following oil change and servicing.
- First oil change at the rst maintenance of the vehicle.
- After that, changing the oil every 5000 operating hours, but at the latest after 3 years.
At the same time the oil lter and the suction lter should be cleaned and the oil collecting ring
from the shaft seal replaced.
Standard oil type used by GEA Bock Recommended alternatives
For HCFC (e.g. R22)
Fuchs Reniso SP 46
BP Energol LPT 46 SUNOCO Suniso 3.5GS
TEXACO Capella WF 46
For HFC (e.g. R134a, R404A, R407C)
Fuchs Reniso Triton SE 55
FUCHS SEZ 32 / 68 / 80 ESSO / Mobil EAL Arctic 46
Lubricants
Information about other suitable oils should be taken from GEA Bock lubricant tables. Information may also be retrieved from vap.gea.com
(mobile applications -> documentation -> technical information -> vehicle compressor -> ... -> lubrication chart).
The oil type charged as standard in the factory is marked on the name plate. This oil type should be used as a preference.
Alternatives are stated in the extract from our lubricants table below:

Other manuals for GEA FK40 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GEA FK40 Series and is the answer not in the manual?

GEA FK40 Series Specifications

General IconGeneral
BrandGEA
ModelFK40 Series
CategoryAir Compressor
LanguageEnglish

Related product manuals