EN
1 Connect the electrofusion machine to
the supply voltage.
ࣜ7
Mains connection LED display
lights up.
2 Connect the connecting cable for
electrofusion coupling to the electro-
fusion sleeve coupling or the electro-
fusion tape for anchor point.
Ready for welding LED display
lights up.
3 Press the start button.
Welding procedure LED display
lights up and the Ready for
welding LED display goes out.
4 After approx. 80 seconds, the
welding is complete and the sleeve
connection plug can be unplugged.

Welding procedure LED display
goes out and the Welding
complete LED display lights
up.
Result
Welding has been performed correctly.