Malfunction Cause Rectification
Malfunction and
Welding procedure LED
displays light up.
Defective Geberit electrofusion
coupling or defective Geberit
electrofusion tape for anchor
point.
▶ Disconnect the mains plug.
▶ Carry out a visual inspection
of the contacts on the
sleeve connection plugs and
dry or clean them if
necessary.
▶ Use a new Geberit electro-
fusion coupling or a new
Geberit electrofusion tape
for anchor point.
Sleeve connection plug
removed during the welding
procedure.
▶ Disconnect the mains plug.
▶ Press the start button and
hold for three seconds.
▶ Repeat the welding
procedure with a cooled
Geberit electrofusion
coupling or cooled Geberit
electrofusion tape for
anchor point.
Malfunction and
Welding complete LED
displays light up.
Electrofusion tool is
overheating or operating at too
high an ambient temperature.
▶ Let electrofusion tool cool
down until the trouble
indication goes out.
▶ Do not expose the electro-
fusion tool to direct sunlight.
Malfunction and Ready
for welding LED displays
light up.
Operating at too low an
ambient temperature.
▶ Only operate the electro-
fusion tool in the permitted
temperature range. For
more information, see
chapter "Technical data",
page22.
Malfunction , Welding
procedure and Ready
for welding LED displays
light up.
Fault current while welding,
e.g. as a result of moisture on
electrical connections.
▶ Disconnect the mains plug.
▶ Keep electrofusion tool, all
cables as well as Geberit
electrofusion coupling or
Geberit electrofusion tape
for anchor point dry and
clean.
Malfunction LED display
flashes.
Electrofusion tool is defective. ▶ Send the electrofusion tool
to an authorised repair
shop. The addresses of
authorised repair shops can
be requested from the
Geberit sales companies.
26
72057596303590795 © 11-2023
967.778.00.0(03)