29MSPA-1-AS
1• Verify if the top side control is
properly connected to the board.
If voltage readings are correct but nothing seems to work, proceed as follows:
3• If the problem still persists, clean the
pins of the transformer orange
connector using a screwdriver (a
small coating of film may cause a bad
connection).
4• If the system still does not work,
replace the transformer.
5• If the problem is not solved yet,
replace the board referring to the
"How to Replace the Board" section
of this manual.
2• If the problem persists, replace the
transformer fuse (F6).
Transfo
fuse (F6)
TROUBLESHOOTINGNothing Works!