13MSPA-MP Metapacks Service Manual
Flashing Dots Displayed
6 Ensure adequate water flow in the
heater and short two pressure switch
terminals with jumper cable.
7 If the three dots disappear, first
make sure there is no blockage of
water or air lock and check water
valve.
If the installation is older than 2 years,
replace the pressure switch and re-
calibrate it.
If installation is recent, try readjust-
ing the pressure switch. If this is not
possible, replace switch.
(Refer to "How to Adjust the
Pressure Switch" section of this
manual.)
8 If the three dots still appear, the
problem may be either with switch
cable or board.
Remove plastic cover and replace
cable.
9 Replace board if error condition still
persists. (Refer to "How to Replace
the Board" section.)