61MSPA-MP Metapacks Service Manual
Circulation Pump Flow Chart
If circulation pump does not appear to be working, follow Troubleshooting
Flow Chart below to identify the problem:
Replace
circulation
pump fuse.
Replace
circulation pump.
Replace
board.
Do you
read
120 VAC for
120 VAC circ. pump
(or 240 VAC for 240 VAC)
at circ. pump
output on
the board?
Increase set point to
2° above actual water temp.
to start circulation pump.
Verify if low level
programming has been
programmed properly
(see Low Level Section).
yes no