SCCB TYPE G-202-P00 Service Manual for Producers Page 13
PPUH „GECO” EDITION I PRINTOUT DATE 2014-03-27
VIII. SYSTEM PARAMETERS PROGRAMMING
Having activated and checked the unit operation (standard settings are factory set), start entering system
parameters to the G-202-P00 unit.
For this purpose, turn off the unit by pressing the pushbutton. Then press the buttons and ,
depress and hold, at the same time press the pushbutton. All the three pushbuttons need to be
depressed and held for at least the period of 3 seconds. If any of these buttons has been released during the
said time, the unit will abandon the programming mode. When the unit has assumed the programming mode,
the LEDs on the and pushbuttons will start to blink, while the display will show the ‘c0’ per one second.
Then, the value of this parameter most recently programmed will be shown. Enter the required settings, using
the pushbuttons, any longer pushbutton holding time causing the data “fast rewinding/forwarding”.
Then press , in order to approve the data entered and start entering the next parameter.
Partial entering of the settings is also possible. If any alteration of the particular setting is not required,
simply press the pushbutton and the G-202-P00 unit will assume the next parameter setting mode.
Note !!!
The refrigeration unit Manufacturer may block access to a portion of or even to all parameters
available from the keyboard, by means of the computer programming unit. If this is the case,
and the alteration of any of the blocked parameters is attempted, the display will show the ‘bL’
symbol for the period of 1 second.
Remarks on SCCB programming.
1. IT IS THE RESPONSIBILITY OF THE MANUFACTURER OF THE REFRIGERATING UNIT AND THE SERVICE
ENGINEER TO ENTER NEW SETTINGS REQUIRED FOR NORMAL FUNCTIONING OF THE UNIT !!!
2. Do the programming carefully, preferably writing down earlier the values of the particular parameters on a
sheet of paper. Remember that any error made when programming some parameters will have very
serious consequences including damage of the product and the refrigerating unit.
3. Having programmed and started the unit check it for proper operation and recheck if the settings of the
system parameters are correct.
4. Transfer of the Service Instructions or any information regarding the mode of programming the SCCB
system parameters to the end user is absolutely not allowed. The end user should receive only and
exclusively a copy of the section XIII of these instructions.