inp.2
al.xb
0Vt.P
sp
212
5 • PROGRAMMING and CONFIGURATION
F
If Inc, Dec, F keys are not pressed within 30 sec, display returns automatically to PV/SV value.
All INFO and dAtA data on config menu remain displayed and are not timed.
INFO
P.V. / S.V.
Process variable (PV display)
Work Setpoint (SV display) or control
output value with regulator in manual
Amperometric input value or remote
Setpoint (with auxiliary input enabled)
Alarm point 1 (scale points)
Alarm point 2 (scale points)
Alarm point 3 (scale points)
Heater break alarm point (scale
points of ammeter input)
Control output value
(+Heat / -Cool)
Press for
approx.
2 sec
Control parameters
dAtA
CFG
SEr
InP
Out
PASS = 99
Prot
Lin
CuSt
Serial communications
Input settings
Output settings
Hardware configuration
Input linearization
“dAtA” menu setting
_CAL
Select calibration menu [ 0...12 ]
YES
NO
Keep the F key
pressed to scroll
the menus
Release the F
key to select the
displayed menu
Press the F key
to access the
parameters
Keep the F key
pressed to exit any
menu
Keep F + Auto/Man
keys pressed for 2
sec. on any menu
to go immediately
to level 1 display
(*)
(*)
S3 = ON
Local Setpoint
LEVEL 1 MENU
PASS
NO
YES
Hrd
U.CAL
S4 = ON
YES
NO
Custom menu
Password
User calibration
Protection code
(*) The automatic return PV/SV display is disabled for these displays
1
2
3
4
5
6
7
Information display
Setpoint 1
Setpoint 2
Setpoint 3
Setpoint 4
Limit value of timer
0 ... 9999 sec
N.B.: Once a particular configuration is entered, all unnecessary parameters are no longer displayed
213
214
215
217
Device structure: identification of boards
-
-
SP.1
-
SP.2
-
SP.3
-
SP.4
-
ts
--
al.1
-
al.2
-
al.3
-
DISPLAY BOARD
POWER BOARD
CPU BOARD
W BOARD
SERIAL BOARD
3
80225E_MHW_800_04-2013_ENG