22 ADV50 QS, SW-PW V1.11 / CTL V2.11
Italiano English
Italiano English
Pr. Explanation Settings
Factory
Setting
NOTE
08.04
Momentary Power
Loss Operation
Selection
0: Operation stops after momentary power loss
1: Operation continues after momentary power
loss, speed search starts with the Master
Frequency reference value
2: Operation continues after momentary power
loss, speed search starts with the minimum
frequency
0
08.05
Maximum Allowable
Power Loss Time
0.1 to 5.0 sec 2.0
08.06
Base-block Speed
Search
0: Disable speed search
1: Speed search starts with last frequency
command
2: Starts with minimum output frequency
1
08.07
B.B. Time for Speed
Search
0.1 to 5.0 sec 0.5
08.08
Current Limit for
Speed Search
30 to 200% 150
08.09
Skip Frequency 1
Upper Limit
0.00 to 600.0 Hz 0.00
08.10
Skip Frequency 1
Lower Limit
0.00 to 600.0 Hz 0.00
08.11
Skip Frequency 2
Upper Limit
0.00 to 600.0 Hz 0.00
08.12
Skip Frequency 2
Lower Limit
0.00 to 600.0 Hz 0.00
08.13
Skip Frequency 3
Upper Limit
0.00 to 600.0 Hz 0.00
08.14
Skip Frequency 3
Lower Limit
0.00 to 600.0 Hz 0.00
08.15
Auto Restart After
Fault
0 to 10 (0=disable) 0
08.16
Auto Reset Time at
Restart after Fault
0.1 to 6000 sec 60.0
0: Disable
08.17 Auto Energy Saving
1: Enable
0
08.18 AVR Function
0: AVR function enable
1: AVR function disable
2: AVR function disable for decel.
3: AVR function disable for stop
0
08.19
Software Braking
Level
230V series: 370.0to 430.0V
460V series: 740.0 to 860.0V
380.0
760.0
a08.20
Compensation
Coefficient for Motor
Instability
0.0~5.0 0.0
08.21 OOB Sampling Time 0.1 to 120.0 sec 1.0
08.22
Number of OOB
Sampling Times
00 to 32 20 08.22
08.23
OOB Average
Sampling Angle
Read only ## 08.23
08.24
DEB Function
DEB Return Time
0: Disable
1: Enable
0 08.24
08.25 OOB Sampling Time 0 to 250 sec 0 08.25
Group 9 Communication Parameters
a09.00
Communication
Address
1 to 254 1