11.3 - HOW TO STOP THE SOFTENER
If the softener has not been used for a period longer than 10-14 days, it is necessary to unplug the power
supply, close the on-off valves before and after the system and open the by-pass gate valve (see installation
drawings at sections 9.2 – 9.3).
After this non-use period, connect the power supply again, open the on-off valves before and after the
system and close the by-pass gate valve.
Carry out a manual regeneration. To launch this operation, press key
+
A
BR
.
12 - MAINTENANCE
For a proper working of the softener, periodically carry out the following operations:
OPERATION FREQUENCY
(days)
OPERATOR
Cleaning of the filter
cartridge before the
softener
60 User
Cleaning of the brine
tank
180 User
Check and refill of salt
in the brine tank
15 User During start up, according to the
model of softener and regeneration
frequency, the technician will
recommend the user on the most
suitable frequency for this inspection
Check of the hardness
of the produced water
through the special kit
(see section 11.2)
60 User If hardness is higher than 15 °f,
please call the authorized Technical
Assistance Service, carrying out
the start up and testing, for any
inspections and adjustments
Check of the exact
time on the timer
60 User
Softener overhaul 365 Technical
Assistance
Service