www.gemu-group.com6 / 19GEMÜ 1441
Technical data
Medium
Working medium: Compressed air and inert gases
Dust content: Class 4, max. particle size 15 μm, max. particle density 5 mg/m³
Pressure dew point: Class 4 (10 K below the ambient temperature)
Oil content: Class 4, max. oil concentration 25 mg/m³
Quality classes to DIN ISO 8573-1
Temperature
Ambient temperature: -10 — 60 °C
Storage temperature: -10 — 60 °C
Pressure
Operating pressure: 1.5 — 7 bar
The applied pressure must not exceed the maximum control pressure of the process valve.
Flow rate: 115 Nl/min (@ 25°C; 6->5 bar)
Air consumption: ≤ 0.05 Nl/min (when idle)
Product compliance
EMC Directive: 2014/30/EU
Technical standards used:
Interference emission: DIN EN 61000-6-3:2007/A1:2011/AC:2012
DIN EN 61326-1 (industry) (07/2013)
Interference resistance: EN IEC 61000-6-1:2019
EN 61326-1:2013 (industry)
Class: B
Group: 1
Radio Equipment Direct-
ive (RED):
2014/53/EU
Technical standards used:
Standard regarding the use
of radio frequencies:
EN 300 328 V2.2.2 (2019-07)
Electromagnetic compatibil-
ity (EMC) for radio devices
and services:
EN 301 489-1 V2.2.3 (2019-11)
EN 301 489-17 V3.2.4 (2020-09)
Electrical safety: EN 61010-1:2010 + A1:2019 +
A1:2019/AC:2019
Technical data