EasyManua.ls Logo

GEM 653 - Page 22

GEM 653
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
653, 654
22 / 28
7Y
1
X6
Mounting of proximity switch
Proximity switches are set when the valve is
completely assembled (with valve body).
Setting the proximity switch for the
OPEN position:
G Remove upper screw 4 (see delivery
condition on page 21) from bonnet.
G Move the bonnet to the open position.
G At least 2/3 of the damping cam 3 must
be visible.
Otherwise please proceed as follows:
• Remove threaded plug 1.
• Loosen grub screw 2 by 1-1.5 turns.
Do not unscrew grub screw 2 more than
that to prevent it from falling inside the
valve.
• Correct the position of the damping
cam 3.
• Secure the position of damping cam 3
by fixing it with grub screw 2.
• Screw in threaded plug 1.
G Screw in proximity switch 6 until it
touches damping cam 3.
G Turn back proximity switch 6 by 1/2 to 3/4
turns.
G Secure this position by fixing it with nut X.
Setting the proximity switch for the
CLOSED position:
G Remove lower screw 5 (see delivery
condition on previous page) from bonnet.
G Move the bonnet to the closed position.
G At least 2/3 of the damping cam 3 must
be visible.
Otherwise please proceed as follows:
• Remove threaded plug 1.
• Loosen grub screw 2 by 1-1.5 turns.
Do not unscrew grub screw 2 more than
that to prevent it from falling inside the
valve.
• Correct the position of the damping
cam 3.
• Secure the position of damping cam 3
by fixing it with grub screw 2.
• Screw in threaded plug 1.
G Screw in proximity switch 7 until it
touches damping cam 3.
G Turn back proximity switch 7 by 1/2 to 3/4
turns.
G Secure this position by fixing it with nut Y.
5
4
1
3
2
Setting the damping cam