之间无遮挡),屏幕从L-01跳到L-02,此时无布学习
完成;再用缝料把前后光电感应都遮住,进行布料学
习,按S键,当屏幕显示SC表示学习成功;如显示FA,
则表示学习失败,请检查确认接插口等硬件没问题后
重新检测学习。
Press P to P- 00, Press Speed+ to P- 15, Press S and
parameter by default is 0, Press Speed+ to 1, Press S
to adjust the sensor without fabric, display from L-01
to L-02, means adjustment done; usefabric to hide all
sensor, to adjust the sensor with fabric. Press S, dis-
play SC means adjustment done ;if display FA means
failed, check all connection and re- adjust.
③LED灯亮度调节(P-27):
LED light brightness adjustment
长按P键进入P-00,按减速键到P-27;按S进入参数默认
显示4,根据实际需要调节LED灯亮度,按加速键亮度
调高,按减速键亮度调低。
Press P to P- 00, Press Speed- to P- 27, press S,
parameter by default is 4, adjust the LED light
brightness according to need.
④前剪线头长度调节(P-17):
Before sewing thread chain length adjust
长按P键进入P-00,进入P-17默认显示0,如线头太长则
把数值略微调大再测试(根据针距大小调节参数数
值,针距越大则对应参数数值应该越小,否则容易不
剪线),确认后按S保存,再按P退出参数界面。
Press P to P- 00, press Speed+ to P- 17, the parame-
ter by default is 0, adjust the parameter to adjust the
thread chain length after cut. (Please adjust the para-
meter according to the needle gauge) press S to save
and press P to exit the setting.
⑤恢复出厂设置(P-07):Factory setting
长按P键进入参数界面,进入P-07参数显示0,按加速键
到1,再按S保存,按P退出参数界面,即恢复出厂设置.
Press P to setting mode. Press Speed+ to P-07, parameter
by default is 0, adjust to 1 and press S to save. Press P to
exit the setting mode.
3
参数号 参数名称 出厂设置 调整范围
备注
最高速度限制
Max.Speed
方向锁定设置
Rotation Direction
开机针位设置
Start Needle
Position
加速曲线
Accelerating Curve
速度模拟设置
Speed Simulate
Setting
起缝速度
Start Speed
电流设置
Currency Setting
恢复出厂设置
Factory Setting
电机级数设置
Motor Setting
5500
P-08
P-05
P-06
P-07
P-04
P-02
P-03
P-01
P-00
0
1
1
9
200
4
4
0
3-4
150-800
0-9
0-1
0-9
1-4
0-1
0-1-2
150-8000
根据电机型号设定;单位:RPM;用户无需设置;
Adjust according to the motor model . RPM
0是一级菜单可以调试。1是顺转,2是逆转;用户无需设置;
0:testing.1,Clock direction.2,Reversion direction.
0:开机无针位自选,1:自动选择上位针
0:NO position,1:Upper position
数值越大,踏板低速行程越短,如无特别需要,建议不要操作;
Parameter increase,speed up faster. suggest no adju-
stment
0~9档对应当前最高转速的82~100%,每档差2%;用户无需设
置; 0~9refect to the current max.Speed's 82~100%,
2%each setting.
数字越大起缝速度越快;单位 RPM;
Parameter to the start speed.RPM
厂家根据电机规格设定;用户无需设置;
No need adjustment
设为1时恢复出厂设置;
Parameter to 1 is factory setting.
数值越大输出扭矩越大;用户无需设置;
Parameter bigger,output torque bigger
抬压脚发射管
Footlifter sensor
(sent)
前剪发射管
Before sewing thread
cutter sensor(sent)
后剪发射管
After sewing thread
cutter sensor(sent)
抬压脚接收管
Footlifter
sensor
(receive)
P-09
P-10
P-11
P-12
P-13
前剪接收管
Before sewing thread
cutter sensor
(receive)
5
5
5
130
130
1-10
1-10
1-10
0-200
0-200
光电发射强度调整;用户无需设置;(E2专用)
No need adjustment(E2 only)
光电发射强度调整;用户无需设置;
No need adjustment
光电发射强度调整;用户无需设置;
No need adjustment
光电接收灵敏度调整;用户无需设置;(E2专用)
No need adjustment (E2 only)
光电接收灵敏度调整;用户无需设置;
No need adjustment