7000EXL Extended Life Generator
15
TROUBLESHOOTING
Problem
Cause
Correction
Engine is running, but no
AC output is available.
1. One of the circuit breakers is open.
2. Fault in generator.
3. Poor connection or defective cord set.
4. Connected device is bad.
1. Reset circuit breaker.
2. Contact local service facility.
3. Check and repair.
4. Connect another device that is in
good condition.
Engine runs good at no-
load but “bogs” down"
when loads are connected.
1. Short circuit in a connected load.
2. Generator is overloaded.
3. Shorted generator circuit.
1. Disconnect shorted electrical load.
2. See “Don't Overload Generator”.
3. Contact local service facility.
Engine will not start; or
starts and runs rough.
1. Fuel Valve is in the “Off” position.
2. Failed battery.
1. Turn the fuel valve to the “On
position.
2. Replace battery.
Engine shuts down during
operation.
Out of gasoline.
Fill fuel tank.
Engine lacks power.
Load is too high.
See “Don't Overload Generator”.