Maintenance
Owner’s Manual for MLT3060M-K Light Tower 37
Resetting the Maintenance
Alarms (If Equipped)
The PowerZone–DLA will display a warning message
when the unit is due for maintenance or service. The
maintenance or service interval is set at 750 hours of
engine running time. Once the unit has been serviced,
the appropriate maintenance alarm reminder needs to be
reset. The following procedure demonstrates how to
reset the maintenance alarms:
1. With the unit shut down, switch the main circuit
breaker ON (I). After initialization, the controller will
toggle automatically to the Home screen.
2. Press and simultaneously to enter the
navigation menu.
3. See Press or to move to the top of the
screen. Press to enter the Maintenance screen.
4. Press or to highlight the desired alarm that
needs to be reset. Press to start reset.
5. Enter the pin 4444. To do this, press and then
or to adjust the first number of the maintenance
pin. Press to continue to the next number.
Figure 4-1. Entering Maintenance Pin
Winch Use, Operation and
Maintenance
Prior to Use
Inspect rope or cable and replace if damaged.
Check mounting hardware for proper torque and
tighten if necessary.
Gears, ratchet pivot point and shaft bushings must
be kept lubricated with a thin film of oil or grease.
Operation
Raising the Lights:
1. The cable must be securely fastened to the object
being lifted and to the winch drum.
2. Verify the cable and cable attachments are not
damaged. Contact Generac Mobile Products to
order a replacement cable if necessary.
3. Referring to the “Lift / Let Down” decal on the
winch, turn handle according to the specified
direction to lift. The ratchet MUST make a loud
clicking sound while winding the cable.
Lowering the Lights:
Referring to the “Lift / Let Down” decal on the winch, turn
handle according to the specified direction to lower. No
clicking will be heard because the brake system is
activated.
Maintenance
The following procedures should be performed at least
annually:
1. The gears and bushings of the winch must be kept
lubricated. Apply a thin film of grease to the gear
teeth, and oil the bushings as needed.
2. The ratchet pawl pivot point must be kept
lubricated with a thin oil.
NOTE: Do not get oil or grease on the brake mechanism.
003784

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems Magnum MLT3060K and is the answer not in the manual?

Generac Power Systems Magnum MLT3060K Specifications

General IconGeneral
BrandGenerac Power Systems
ModelMagnum MLT3060K
CategoryWork Light
LanguageEnglish

Related product manuals