EasyManua.ls Logo

General Climate GC-S07HR - User Manual

Default Icon
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Climatic Control Corporation Wall-Mounted Split Type
Service manual
Room air conditioner
Split Wall-Mounted Type
GC/CU-S05CR
GC/CU-S07HR
GC/CU-S09HR
GC/CU-S12HR
GC/CU-S18HR
Question and Answer IconNeed help?

Do you have a question about the General Climate GC-S07HR and is the answer not in the manual?

Summary

1. Precaution

1.1 Safety Precaution

General safety instructions to prevent injury and property damage.

1.2 Warning

Warnings related to installation, operation, and potential hazards.

1.3 CAUTION

Cautions regarding refrigerant leakage, water drainage, and installation practices.

1.4 Operational Guidelines

Guidelines for safe and proper operation and maintenance of the unit.

2. Function

2.1 Indoor Unit Functions

Details on operational features and controls of the indoor unit.

2.2 Outdoor Unit Functions

Details on features and components of the outdoor unit.

3. Dimension

3.1 Indoor Unit Dimensions

Specifies the physical dimensions of the indoor unit.

3.2 Outdoor Unit Dimensions

Specifies the physical dimensions of the outdoor unit.

4. Specification

5. Refrigerant Cycle Diagram

5.1 Cooling Only Cycle

Diagram showing refrigerant flow for cooling operation only.

5.2 Heat Pump Mode Cycle

Diagram showing refrigerant flow for heat pump operation.

6. Operation Limits

6.1 Cooling Operation Limits

Specifies the outdoor and indoor temperature range for cooling.

6.2 Heating Operation Limits

Specifies the outdoor and indoor temperature range for heating.

7. Diagrams

7.1 Schematic Diagram

Detailed electrical schematic of the unit's circuitry.

7.2 Wiring Diagram (GC;GU-S05 CR)

Electrical wiring diagram for the GC/GU-S05CR model in cooling mode.

7.3 Wiring Diagram (Other Models)

Electrical wiring diagrams for GC/GU-S07HR, S09HR, S12HR models.

8. Installation Details

8.1 Wrench Torque for Installation

Specifies torque values for installation fasteners.

8.2 Connecting Cables

Guidelines for selecting and connecting power cables.

8.3 Pipe Length and Elevation

Details on refrigerant pipe length and elevation limits.

8.4 Air Purging Procedure

Steps for removing air from the refrigerant piping and indoor unit.

8.5 Pumping Down Procedure

Steps for removing refrigerant before re-installation.

8.6 Re-air Purging Procedure

Steps for re-purging air after re-installation.

8.7 Balancing Refrigerant

Procedure to balance refrigerant in 2-way and 3-way valves.

8.8 Evacuation Procedure

Steps for creating a vacuum in the refrigeration system.

8.9 Gas Charging Procedure

Steps for charging the system with refrigerant.

9. Capacity Tables

9.1 GC;GU-S05 CR Capacity

Cooling capacity table for GC/GU-S05CR model.

9.2 GC;GU-S07 HR Capacity

Cooling and heating capacity table for GC/GU-S07HR model.

9.3 GC;GU-S09 HR Capacity

Cooling and heating capacity table for GC/GU-S09HR model.

9.4 GC;GU-S12 HR Capacity

Cooling and heating capacity table for GC/GU-S12HR model.

9.5 GC;GU-S18 HR Capacity

Cooling and heating capacity table for GC/GU-S18HR model.

10. Electronic Functions

10.1 Electronic Control Working Environment

Specifies voltage, frequency, and ambient conditions for electronic operation.

10.2 Proper Symbols and Their Meaning

Explains symbols used for temperatures, currents, and protections.

10.3 Function Descriptions

Lists and briefly describes various operational functions of the unit.

10.4 Protection Mechanisms

Details various protection features like delay, sensor, current, and cross-zero signals.

10.5 Fan-Only Mode

Describes operation when only the fan is active.

10.6 Cooling Mode

Details operation of compressor and fan during cooling.

10.7 Dehumidifying Mode

Explains functions and compressor/fan actions in dehumidifying mode.

10.8 Heating Mode Operations

Covers heating mode functions, fan actions, and protections.

10.9 Defrosting Mode

Conditions and actions for the defrosting mode.

10.10 Auto Mode

Automatic selection of cooling, heating, or fan-only modes.

10.11 Force Cooling Function

How to activate and operate the forced cooling mode.

10.12 Sleep Mode

Features and operation of the sleep mode for cooling, heating, and auto.

10.13 Auto Restart Function

Automatically restores previous settings after power failure.

10.14 Anion (Optional)

Description of the optional anion function.

11. Model and Parameters

12. Troubleshooting

12.1 Display Board Indicators

Explains the meaning of the indicators on the display board.

12.2 Troubleshooting Guide

Lists failure phenomena and corresponding indicator states for diagnosis.

12.3 Diagnostic Chart

Flowchart for troubleshooting when the unit is not operating.

12.4 Resetting Phenomenon

Troubleshooting steps for resetting during operation.

12.5 Operation Lamp Flashing (Timer Off)

Troubleshooting for lamp status when Timer is off.

12.6 Operation Lamp Flashing (Timer On)

Troubleshooting for lamp status when Timer is on.

12.7 Operation Lamp Off & Timer Flashes

Troubleshooting for lamp status when Operation is off and Timer flashes.

12.8 Operation Lamp On & Timer Flashes

Troubleshooting for lamp status when Operation is on and Timer flashes.

12.9 Operation & Timer Lamps Flashing

Troubleshooting for simultaneous flashing of Operation and Timer lamps.

13. Temperature Sensor Characteristics

General Climate GC-S07HR Specifications

General IconGeneral
BrandGeneral Climate
ModelGC-S07HR
CategoryAir Conditioner
LanguageEnglish

Related product manuals