www.generalclimate.com Wall-Mounted Split Type
Service manual
Room air conditioner
Split Wall-Mounted Type
GC/GU-S24HR
GC/GU-S30HR
GC/GU-S36HR
Question and Answer IconNeed help?

Do you have a question about the General Climate GU-S36HR and is the answer not in the manual?

Summary

1. Precautionary Measures

1.1 Safety Precautions

General safety instructions to prevent injury, property damage, and incorrect operation.

1.2 Installation Safety

Critical warnings and guidelines for safe installation of the unit.

1.3 Operational Safety

Important safety instructions and precautions for operating the air conditioner.

2. Unit Functions

2.1 Indoor Unit Functions

Lists and describes various operational features of the indoor unit.

2.2 Outdoor Unit Functions

Lists and describes various operational features of the outdoor unit.

3. Dimensions

3.1 Indoor Unit Dimensions

Provides physical dimensions (W, H, L) for the indoor unit.

3.2 Outdoor Unit Dimensions

Provides physical dimensions (W, H, D, L1-L3) for the outdoor unit.

4. Specifications

4.1 Model Specifications

Comprehensive technical data for all GC/GU-S models.

5. Refrigerant Cycle Diagrams

5.1 Cooling Only Cycle

Illustrates the refrigerant flow for cooling-only operation.

5.2 Heat Pump Cycle

Illustrates the refrigerant flow for heat pump operation.

6. Operation Limits

6.1 Cooling Operation Limits

Chart showing acceptable temperature ranges for cooling.

6.2 Heating Operation Limits

Chart showing acceptable temperature ranges for heating.

7. Diagrams

7.1 Schematic Diagram

Detailed electronic circuit schematic for the air conditioner.

7.2 Wiring Diagram

Electrical wiring diagrams for indoor/outdoor units (S24HR/S30HR).

7.3 Wiring Diagram

Electrical wiring diagrams for the outdoor unit (S36HR).

8. Installation Details

8.1 Installation Preparations

Covers tools, torque, cable, and pipe connection guidelines.

8.2 Air Purging Procedure

Step-by-step guide to remove air from the refrigerant system.

8.3 Pumping Down Procedure

Method for recovering refrigerant before re-installation.

8.4 Re-air Purging Procedure

Steps to purge air again after re-installation.

8.5 Balance Refrigerant

Method for balancing refrigerant charge in the system.

8.6 Evacuation

Process for creating a vacuum in the refrigerant system.

8.7 Gas Charging

Steps for charging the system with the correct refrigerant amount.

9. Capacity Tables

9.1 GC;GU-S24 HR Capacity

Cooling and heating capacity data for the S24HR model.

9.2 GC;GU-S30 HR Capacity

Cooling and heating capacity data for the S30HR model.

9.3 GC;GU-S36 HR Capacity

Cooling and heating capacity data for the S36HR model.

10. Electronic Functions

10.1 Control Environment & Symbols

Operating conditions for electronic control and meanings of symbols.

10.2 General Functions

Lists operational features (Fan Only, Cooling) and protection mechanisms.

10.3 Dehumidifying & Heating Modes

Describes dehumidifying and heating mode operations.

10.4 Heating Mode Details

Further heating details, fan actions, and protections.

10.5 Defrosting Mode

Explains the defrosting mode conditions and actions.

10.6 Auto, Force Cooling, Sleep Modes

Covers auto mode selection, forced cooling, and sleep functions.

10.7 Auto Restart Function

Functionality for resuming operation after power failure.

11. Model and Parameters

11.1 Parameter Overview

Lists operational parameters for different models.

12. Troubleshooting

12.1 Display Board Indicators

Explanation of indicator lights on the unit's display board.

12.2 Failure Phenomena

Lists failure symptoms and corresponding indicator states.

12.3 Diagnostic Chart

Flowchart for diagnosing issues when the unit is unresponsive.

12.4 Resetting Phenomenon

Diagnosing frequent resetting during operation due to voltage issues.

12.5 Specific Lamp Flash Patterns

Troubleshooting specific combinations of flashing lamps.

13. Temperature Sensor Characteristics

13.1 Sensor Resistance Data

Table showing resistance values for temperature sensors at different temperatures.

General Climate GU-S36HR Specifications

General IconGeneral
TypeSplit System
Cooling capacity36000 BTU/h
Refrigerant typeR410A
Air Flow (Indoor Unit)1200 m³/h
Power Supply220-240V/50Hz
Energy Efficiency Ratio (EER)3.0
Operating Temperature (Cooling)+18 to +43 °C