Do you have a question about the General Climate GC-S09HR and is the answer not in the manual?
General safety instructions to prevent injury and property damage.
Warnings related to product installation to avoid hazards.
Warnings for safe operation and to prevent product damage or hazards.
Important advisories for installation, maintenance, and usage.
Details on the operational functions and features of the indoor unit.
Details on the operational functions and features of the outdoor unit.
Technical specifications for the physical size of the indoor unit.
Technical specifications for the physical size of the outdoor unit.
Diagram illustrating the refrigerant flow in cooling mode.
Diagram illustrating the refrigerant flow in heat pump mode.
Chart defining the operational temperature range for cooling.
Chart defining the operational temperature range for heating.
Electrical schematic illustrating the circuit layout.
Electrical diagrams showing connections for different models.
Torque values for installation fasteners.
Guidelines for selecting power cord specifications.
Guidelines for piping length and vertical installation.
Steps for removing air from the piping and unit.
Procedures for refrigerant recovery and re-purging.
Steps for balancing refrigerant and system evacuation.
Procedure for charging the system with refrigerant.
Cooling capacity data for the GC/GU-S05CR model.
Cooling and heating capacity data for the GC/GU-S07HR model.
Cooling and heating capacity data for the GC/GU-S09HR model.
Cooling and heating capacity data for the GC/GU-S12HR model.
Cooling and heating capacity data for the GC/GU-S18HR model.
Working environment, symbols, and their meanings.
List of main electronic functions and features.
Details on protection features and fan-only mode.
Operation details for cooling and dehumidifying modes.
Operation details for heating and defrosting modes.
Operation of auto, forced cooling, and sleep modes.
Auto restart function and optional anion feature.
Explanation of display indicators and common failure tables.
Flowchart for operation issues and resetting phenomena.
Diagnosing issues based on operation/timer lamp status.
| Cooling capacity | 9000 BTU/h |
|---|---|
| Refrigerant type | R410A |
| Power Supply | 220-240V, 50Hz |
| Noise Level (Outdoor) | 50 dB |
| Refrigerant | R410A |
| Weight (Indoor Unit) | 8 kg |
| Type | Split system |
| Power consumption during cooling | 0.82 kW |
| Power Consumption (Cooling) | 0.82 kW |
| Operating Temperature (Cooling) | +18 to +43 °C |
| Operating Temperature (Heating) | -7°C to 24°C |
| Dimensions (Outdoor Unit) | 700 x 480 x 240 mm |

