Physical dimensions (W, H, L) for various indoor unit models.
Physical dimensions (W, H, D, L1, L2, L3) for various outdoor unit models.
Details on power, capacity, EER, refrigerant, and piping.
Specs for compressor, indoor/outdoor fan motors, and capacitors.
Visual representation of refrigerant flow in cooling and heat pump modes.
Charts defining acceptable indoor/outdoor temperature ranges for cooling and heating.
Electrical schematics and wiring diagrams for unit operation.
Required torque for installation and power cord specifications.
Limits on pipe length, elevation, and additional refrigerant guidelines.
Steps for air purging, pumping down, evacuation, and gas charging.
Cooling and heating capacity tables for specific models under various conditions.
Cooling and heating capacity tables for specific models under various conditions.
Cooling and heating capacity tables for the S18HR model under various conditions.
Specs, symbols, and basic functions like remote receiving, timer, and LED indicators.
Details on fan-only, cooling, dehumidifying, heating, and defrosting modes.
Explains auto mode, sleep, auto restart, forced functions, and anion features.
Table of protection parameters (ISEC, I MIN, IFAN, I RESTORE, I DEFROST) and temperature thresholds.
Table of angle settings and defrost temperature difference parameters.
Explains display indicators and failure phenomena for unit operation.
Guides for diagnosing issues like no operation, resetting, and common failures.
Table of resistance values for temperature sensors used in diagnostics.
Lists parts for the GC-S05CR indoor unit with sale codes.
Lists parts for GC-S07HR and GC-S09HR indoor units with sale codes.
Lists parts for GC-S12HR indoor units with sale codes.
Lists parts for GC-S18HR indoor units with sale codes.
Lists parts for the GU-S05HR outdoor unit with sale codes.
Lists parts for the GU-S07HR outdoor unit with sale codes.
Lists parts for the GU-S09HR outdoor unit with sale codes.
Lists parts for the GU-S12HR outdoor unit with sale codes.
Lists parts for the GU-S18HR outdoor unit with sale codes.
| Power Supply | 220-240V, 50Hz |
|---|---|
| Refrigerant | R410A |
| Weight (Indoor Unit) | 7.5 kg |
| Weight (Outdoor Unit) | 23 kg |
| Noise Level (Outdoor) | 50 dB |
| Power consumption (cooling) | 1095 W |
| Type | Split System |
| Cooling Capacity | 12000 BTU |
| Heating Capacity | 12000 BTU/h |
| Operating Temperature (Cooling) | +18 to +43 °C |