14
GAS INSTRUCTIONS
Check: 
A)  Flexible Hose to bulkhead connection (1).
B)  Main gas line to bulkhead connection (2). 
C)  Main gas line to manifold connections (3).
D)  Side burner gas line to manifold connection (4).
E)  Side burner pipe fitting to side burner cup (5).
F)  Side burner pipe fitting to side burner valve connections (6).
m  WARNING: If there is a leak at connection (1, 2, 3, 4, 5, or 6), 
retighten the fitting with a wrench and recheck for leaks with 
soap and water solution. If a leak persists after re-tightening 
the fitting, turn OFF the gas. DO NOT OPERATE THE GRILL. 
Contact the Customer Service Representative in your area 
using the contact information on our web site.  
Log onto www.weber.com
®
.
G)  Side burner quick disconnect connection (7).
H)  Flexible Hose to Quick Disconnect connection (8).
I)  Valves to manifold connections (9). 
m  WARNING: If there is a leak at connections (7, 8, or 9), turn 
OFF the gas. DO NOT OPERATE THE GRILL. Contact the 
Customer Service Representative in your area using the 
contact information on our web site.  
Log onto www.weber.com
®
.
When leak checks are complete, turn gas supply OFF at the source and rinse 
connections with water.
Reinstall Control Panel
You will need: Phillips screwdriver.
J)  Position top edge of control panel on tabs of frame. Push down into position. 
K)  Reinstall igniter module.
L)  Slide both shorter wind deflector tabs toward inside edge of control panel while you 
slide longer tab over outside edge. Seek previous illustrations for reference.
M)  Line up screws with screw holes on both control panel bracket and frame.
N)  Tighten screws.
O)  Place corresponding control knobs onto valve stems. 
◆
The grill illustrated may 
have slight differences 