EasyManua.ls Logo

GEZE GC 363 R - Technical data

GEZE GC 363 R
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
31
Fault messages and troubleshootingGC 363 R / SF
LCD
display
Eect Cause Elimination
The RED LED
ashes quickly
after teach-in
with door move-
ment
The sensor senses
the door during
teach-in with door
movement.
X
Remove AIR curtains from
the door.
X
Install the sensor as close as
possible to the door.
Use installation accessories if
necessary.
X
Start teach-in with door
movement. Move out of the
detection area for this.
The RED LED
lights up sporad-
ically
The sensor is
vibrating.
X
Check whether the sensor has
been xed in place correctly.
X
Check the position of cable
and cover.
The sensor senses
the door.
X
Start teach-in with door
movement and change the
AIR angle.
Elements in the
environment are
interfering with
the sensor.
X
Increase AIR immunity lter
to 3.
X
Select default setting 2 and 3.
The GREEN LED
lights up sporad-
ically
Rain or falling
leaves are inter-
fering with the
sensor.
X
Select default setting 2 and 3.
X
Increase the radar immunity
lter.
Phantom open-
ing through door
movement.
X
Change radar angle.
The sensor is
vibrating.
X
Check whether the sensor
and door prole have been
xed in place correctly.
X
Check the position of cable
and cover.
The sensor senses
the door or other
moving objects.
X
Remove objects if possible.
X
Change radar eld size or
angle.
The LED and
the LCD display
are o
X
Check the wiring.