EasyManua.ls Logo

Ghost Controls TSS1 - Connecting Arm to Control Box

Ghost Controls TSS1
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
© G host C ontr o l s
®
2 0 2 0
CONNECTING OPERATOR ARM TO CONTROL BOX
STEP 9. Insert the operator cable into the control box.
A. Route the operator cable through the same strain relief as
the battery harness cable and into the control box.
B. Connect the operator wires to the control board. Find the 1st
operator screw terminal on control board and insert the red,
black, green and white wires (left to right) into the matching
color coded terminals and tighten each of the screws so that
the wires do not come loose and fall out.
C. Make sur
e wires are not inserted too far into the terminal slots
and that the wire insulation is not interfering with
contact to the system control board.
D. Tighten strain relief nuts on the control box to close the seals
around the wires.