2.1 Location
This boiler is not suitable for outdoor installation.
This boiler may be installed in any room, although particular
attention is drawn to the installation of a boiler in a room
containing a bath or shower where reference must be made to
the relevant requirements.
In GB this is the current I.E.E. WIRING REGULATIONS and
BUILDING REGULATIONS.
In IE reference should be made to the current edition of I.S.813
"Domestic Gas Installations" and the current ETCI rules.
2.2 Clearances
The boiler should be positioned so that at least the minimum
operational and servicing clearances are provided, see diagram
2.1.
Additional clearances may be beneficial around the boiler for
installation and servicing.
For flue installations where external access is not practicable,
consideration should be given for the space required to insert
the flue internally, which may necessitate clearance larger than
those specified in diagram 2.1.
2.3 Timber Frame Buildings
If the boiler is to be installed in a timber frame building it should
be fitted in accordance with the Institute of Gas Engineers
document IGE/UP/7/1998. If in doubt seek advice from the local
gas undertaking or Glow-worm.
2.4 Room Ventilation
The boiler is room sealed, so when it is installed in a room or
space, a permanent air vent is not required.
2.5 Cupboard or Compartment Ventilation
Due to the high efficiency and hence low casing temperature of
this boiler, cupboard or compartment ventilation is not necessary.
Leave existing air vents.
2 Boiler Location and Ventilation
Diagram 2.1
12344
+
MINIMUM CLEARANCE FROM
PERMANENT SURFACES
+ A removable compartment door can be
placed at least 5mm in front of the appliance.
5
5
600
150
5
20 20
200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm 24cxi and is the answer not in the manual?

Glow-worm 24cxi Specifications

General IconGeneral
Model24cxi
CategoryBoiler
Output24 kW
MountingWall-mounted
ERP RatingA
Flow Rate (l/min)9.8 l/min
Max. Working Pressure3 bar
Flow Rate at 35°C Rise9.8 l/min
Gas TypeNatural Gas
Electrical Supply230V / 50Hz
DHW Output (kW)24.0 kW
Central Heating Flow Temperature Range30°C - 80°C
Gas Consumption (Max)2.7 m³/h
TypeCondensing Combi Boiler
Dimensions740mm x 418mm x 300mm

Related product manuals