14 Replacement of Parts
Diagram 14.12
Diagram 14.13
PUMP
HEAD
CAP HEAD SCREW (4)
SAFETY
DISCHARGE
VALVE
Diagram 14.14
14.15 Pump (head only)
For access, refer to section 14.1.
Refer to section 12.9 and drain the boiler heating circuit.
Refer to diagram 14.12.
Remove the four cap head screws.
Carefully remove the pump head together with cable. Do not
strain cable.
Support the pump head, unscrew cable cover at the side of pump
head and take off.
Disconnect wiring from pump head.
Reconnect wiring to new pump head and fit cover.
Fit the new pump head with 'O' ring.
Refill, vent and pressurise the boiler.
Check for leaks.
14.16 Safety Discharge Valve
For access, refer to section 14.1.
Refer to section 12.9 and drain the boiler heating circuit.
Refer to diagram 14.13.
Undo the safety discharge valve union and remove from the
pipework.
Remove the securing clip and withdraw the safety discharge
valve.
Fit new 'O' ring.
Refill, vent and pressurise the boiler.
Check for leaks.
14.17 Domestic Hot Water Thermistor
For access, refer to section 14.1.
Refer to section 12.10 and drain the boiler domestic hot water
circuit.
Refer to diagram 14.14.
Disconnect the domestic hot water thermistor electrical
connections
Remove retaining clip.
Withdraw domestic hot water thermistor from its housing.
NOTE: When reconnecting electrical connections, polarity is not
important.
Fit new 'O' ring.
Carry out a functional test of the controls.
14.18 Heating Flow Thermistor
For access, refer to section 14.1.
Refer to diagram 14.15.
Remove the electrical connections from the thermistor.
Remove the retaining clip from the flow pipe.
Note: When reconnecting, the polarity of the wiring to thermistors
is not mportant.
14.19 Heating Return Thermistor
For access, refer to section 14.1.
Refer to diagram 14.15.
Remove the electrical connections from the thermistor.
Remove the retaining clip from the flow pipe.
NOTE: When reconnecting, the polarity of the wiring to thermistors
is not important.
CABLE
COVER
DOMESTIC HOT
WATER
THERMISTOR
RETAINING
CLIP
11694
11495
11496

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm 24cxi and is the answer not in the manual?

Glow-worm 24cxi Specifications

General IconGeneral
Model24cxi
CategoryBoiler
Output24 kW
MountingWall-mounted
ERP RatingA
Flow Rate (l/min)9.8 l/min
Max. Working Pressure3 bar
Flow Rate at 35°C Rise9.8 l/min
Gas TypeNatural Gas
Electrical Supply230V / 50Hz
DHW Output (kW)24.0 kW
Central Heating Flow Temperature Range30°C - 80°C
Gas Consumption (Max)2.7 m³/h
TypeCondensing Combi Boiler
Dimensions740mm x 418mm x 300mm