35 0020008154A
NOTE
Before trying to operate the boiler make sure that :
• All gas supply cocks are open and that the gas supply has
been purged of air.
• There is a permanent mains supply to the boiler.
• There is a heating demand from the external controls.
WARNING.
Always isolate the boiler from the electrical supply before
carrying out any electrical replacement work.
Always check for gas soundness after any service work.
Electrical Testing
Should there be any doubt about the voltage supply to any of the
components, it is possible to carry out a simple electrical test.
Important. On completion of the Service/Fault Finding tasks
which have required the breaking and remaking of the electrical
connections the earth continuity, polarity, short circuit and
resistance to earth checks must be repeated using a suitable
multimeter.
To carry out the electrical test, gain access, as follows:
Hinge down the control box and remove Torx screws and
unhook the rear panel, refer diagram 12.2.
Refer to the Wiring diagram 13.1 and fault finding charts
diagrams 13.2 and 13.3.
13 Fault Finding

Other manuals for Glow-worm 38cxi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm 38cxi and is the answer not in the manual?

Glow-worm 38cxi Specifications

General IconGeneral
Model38cxi
CategoryBoiler
Output38 kW
Efficiency89.2%
Efficiency RatingA
ERP RatingA
Fuel TypeNatural Gas
MountingWall Mounted
Max. Working Pressure3 bar
Electrical Supply230V ~ 50Hz
Flow Rate at 35°C Rise15.7 litres/min
Central Heating Flow Temperature Range30°C to 80°C
TypeCondensing Combi Boiler
Flow Rate15.7 litres/min at 35°C rise