The digital display normally shows the operating temperature
of the unit when there is a central heating demand and gives a
pressure reading when there is no demand or when the appliance
is in the domestic hot water mode.
If the digital display shows pressure less than 0.7bar, re-
pressurise the system to 1bar by gently opening the built in
filling tap underneath the boiler, see diagram 2. A tap extension
tool is provided to facilitate this. Ensure the tap is closed. If the
system repeatedly loses pressure, YOU MUST CONTACT
YOUR INSTALLER OR GLOW-WORM'S OWN SERVICE
ORGANISATION USING THE TELEPHONE NUMBER ON
THE INSIDE FRONT COVER OF THIS BOOKLET.
To Turn the Boiler Off
There is a mains reset switch on the right hand side of the
controls fascia, which will isolate the boiler. However, it is
preferable to leave the electrical supply on whenever possible
to permit operation of the built-in frost protection (see 'Protection
Against Freezing') and daily pump and valve exercise.
To turn off the central heating use the room thermostat or
programmer.
To turn off the domestic hot water turn the hot water temperature
control knob to the minimum setting.
For holiday mode turn both of the temperature knobs to the
minimum setting.
To turn off the boiler for servicing, isolate it from the electrical
supply. To turn it on again follow the instructions given in
'Operation of the Boiler'.
Operating the Boiler - User Instructions
11474
Diagram 2
FILLING
LOOP TUBE
FILLING LOOP TAP
AND EXTENSION TOOL

Other manuals for Glow-worm 38cxi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm 38cxi and is the answer not in the manual?

Glow-worm 38cxi Specifications

General IconGeneral
Model38cxi
CategoryBoiler
Output38 kW
Efficiency89.2%
Efficiency RatingA
ERP RatingA
Fuel TypeNatural Gas
MountingWall Mounted
Max. Working Pressure3 bar
Electrical Supply230V ~ 50Hz
Flow Rate at 35°C Rise15.7 litres/min
Central Heating Flow Temperature Range30°C to 80°C
TypeCondensing Combi Boiler
Flow Rate15.7 litres/min at 35°C rise