ANY ASSISTANCE ?
ANY ASSISTANCE?
9 Fault Finding
In this section fault codes that are
displayed, which CAN be carried out by
the USER to restore appliance operation
(Corrective action: ...). Other fault codes
MUST be solved by a competent person
only.
i
IMPORTANT:
Likeallcondensingboilersitwill
produceaplumeofcondensation
fromtheueterminalincool
weather.
Thisisduetothehigheciency
andhencelowuegas
temperatureoftheboiler.Itis
normalandnotafaultindication.
• If after carrying out this basic advice and
your appliance still does not work, leave
it turned o and contact your competent
person.
Fault
code
Possible
causes
Solution
The
boiler
stops
working
Electrical
circuit
interrupted
Check that there is
no power cut and
that the appliance is
correctly connected.
When electrical
power comes back
on, the appliance
automatically
comes back into
service. If the fault
persists, contact
your Installation/
Servicing company
or Glow-worm
Service.
Fault
code
Possible
causes
Solution
Reset
Press the reset
button, then wait
5 secs. Should a
fault be indicated,
a further 2 more
attempts can be
made.
xx
Fault
A fault is indicated
by a ashing,
alternating 'F' and
number. If the fault
persists after 3 reset
attempts, contact
your Installation/
Servicing company
or Glow-worm
Service.
Lack of
water in the
installation
(< 0.5 bars)
Contact your
Installation/
Servicing company
or Glow-worm
Service, to have your
system checked.
Excess
water in the
installation
With central heating
o, open the vent
(bleed screw) on
a radiator to allow
water to escape and
reduce the pressure
in the heating
circuit, or contact
your Installation/
Servicing company
or Glow-worm
Service.

Other manuals for Glow-worm Easicom 24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm Easicom 24 and is the answer not in the manual?

Glow-worm Easicom 24 Specifications

General IconGeneral
TypeCombi Boiler
Output24 kW
Fuel TypeNatural Gas
MountingWall Mounted
Domestic Hot Water Output24 kW
Max Working Pressure3 bar
Warranty2 years
Dimensions740mm x 418mm x 300mm
Efficiency RatingA
Flow Rate10 l/min
Hot Water Flow Rate10 l/min at 35°C rise

Related product manuals