0020167175_01 - 02/13 - Glow-worm
17.6 Expansion vessel
1
2
Key
1 Expansion vessel
2 Expansion vessel pressure inlet
Check the expansion vessel's supply pressure (see « Technical
Data » chapter) by means of the pressure inlet located on the
expansion vessel. Adjust the pressure if necessary.
Following the installation of a new expansion vessel, ll and
purge the appliance or installation, if necessary.
17.7 Condensate trap
a
Warning:
condensate is mildly acidic. Use protective gloves.
5
3
2
4
1
6
Key
1 Condensate cleaning cap
2 Condensate pipe
3 Condensate outletv
4 Condensate retaining screw
5 Condensate trap
6 Hose
Place a container under the condensate trap (5).
Remove the condensate from the reservoir (1).
Disconnect the condensation discharge (2).
Disconnect the heat exchanger hose (6).
The condense trap will contain water, lift taking care not to spill
the water.
Remove the condensate trap (5) using the retaining screw (4).
Clean the hose, the trap and the siphon, remove any
accumulated dirt.
Reassemble the components, taking care to position the
gaskets correctly.
Start the siphon (3) and ll with water.
MAINTENANCE
- 37 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm ULTIMATE 30c and is the answer not in the manual?

Glow-worm ULTIMATE 30c Specifications

General IconGeneral
Boiler TypeCombi
Fuel TypeNatural Gas
Central Heating Output30 kW
ErP Efficiency RatingA
MountingWall-mounted
CH Output30 kW
DHW Output30 kW
Standard Warranty5 Years