4.7 SHUTDOWN CONDITIONS
Model
Over Voltage (DC)
Under
Voltage
Alarm
Under Voltage (DC)
Shutdown Restart Shutdown Restart
12V
16.5V ±
0.3V
14.5V±
0.3V
10.5V ±
0.3V
10.5V ±
0.3V
12.5V±
0.3V
24V 33V ± 0.5V 29V ± 0.5V 21V± 0.5V 21V ± 0.5V 25V ± 0.5V
Model
Over Temperature Protection
Shutdown Restart
12V
80°C 60°C
24V
OPERATION