Service and Troubleshooting


Copyright © 2019-2020 Goodman Manufacturing Company, L.P.
This manual is to be used by qualied, professionally
trained HVAC technicians only. Goodman does not assume
any responsibility for property damage or personal injury
due to improper service procedures or services performed
by an unqualied person.
RS6621003r3
April 2020
®
is a registered trademark of Maytag Corporation or its related companies and is used under license.
All rights reserved.
TABLE OF CONTENTS
IMPORTANT INFORMATION ............................................ 2
PRODUCT IDENTIFICATION ........................................... 4
SYSTEM OPERATION ...................................................... 6
SCHEDULED MAINTENANCE ....................................... 25
SERVICING ..................................................................... 27
ACESSORIES ................................................................. 45
TROUBLESHOOTING CHART ....................................... 48
WIRING DIAGRAMS ....................................................... 51
Pride and workmanship go into every product to provide
our customers with quality products. It is possible, however,
that during its lifetime a product may require service.
Products should be serviced only by a qualied service
technician who is familiar with the safety procedures
required in the repair and who is equipped with the proper
tools, parts, testing instruments and the appropriate service
manual. 




















Cancer and Reproductive Harm -
www.P65Warnings.ca.gov
0140M00517-A

Questions and Answers

  • C
    cisnerostracyAug 13, 2025
    What to do if Goodman Furnace LED is flashing 1 time?
    • S
      Stacy SmithAug 13, 2025
      If your Goodman Furnace fails to operate and the integrated control module diagnostic LED is flashing once, it indicates a furnace lockout due to excessive ignition retries. This can be caused by a gas interruption. You should locate and correct the gas interruption. Also check the front cover pressure switch operation, including the hose, wiring, and contact operation, and correct if necessary. Other possible solutions include replacing or realigning the igniter, checking the flame sense signal (sanding the sensor if coated or oxidized), checking the flue piping for blockage, proper length, elbows, and termination, and verifying proper induced draft blower performance.
  • T
    Tim ThompsonAug 16, 2025
    How to troubleshoot Goodman Furnace with no LED signal?
    • S
      Sheryl MartinAug 16, 2025
      If your Goodman furnace fails to operate and the integrated control module diagnostic LED provides no signal, ensure that there is 115 and 24 volt power to the furnace integrated control module. Check the integrated control module fuse (3A) and replace it if necessary. Check for possible shorts in the 115 and 24 volt circuits and repair as needed. A faulty integrated control module may also be the cause, so replace it if necessary. The cause may be a manual disconnect switch being OFF, door switch open, or 24 volt wires improperly connected or loose, or a blown fuse or circuit breaker.
  • M
    Maria AdamsAug 20, 2025
    What does 6 flashes mean on a Goodman AMES800603A Furnace?
    • R
      rachel76Aug 20, 2025
      If your Goodman furnace fails to operate and the integrated control module diagnostic LED is flashing six times, it could be due to flame rollout. Check the burners for proper alignment. Also, check the flue and air inlet piping for blockage, proper length, elbows, and termination, and correct as necessary. Check the rollout limit and replace it if necessary. Ensure the induced draft blower is performing properly, and replace it if necessary. The problem may also be due to misaligned burners, a blocked flue and/or air inlet pipe, or a failed induced draft blower. Check and correct any loose or improperly connected wiring. A short in the 24 volt AC control circuits or safety circuits, or a faulty rollout limit can also cause this issue. Tighten or correct any wiring connections.
  • M
    Martha GrantAug 25, 2025
    Goodman AMES800603A flashes 8 times, what does it mean?
    • R
      Ricky MooreAug 25, 2025
      If your Goodman furnace is not operating and the integrated control module diagnostic LED is flashing eight times, check and correct the wiring from the integrated control module to the igniter. Replace the igniter if it is bad. Check and correct the unit ground wire. If the issue persists, replace the integrated control module. This may be caused by an improperly connected igniter, a bad igniter, a poor unit ground, a poor burner ground, or a faulty integrated control module.
  • S
    stacy67Aug 27, 2025
    What does 2 flashes mean on a Goodman AMES800603A?
    • L
      laurahortonAug 27, 2025
      If your Goodman furnace fails to operate and the integrated control module diagnostic LED is flashing twice, it could be due to induced draft blower pressure switch contacts sticking. In this case, replace the induced draft blower pressure switch. It could also be caused by shorts in the pressure switch circuit, which would require repairing the short.
  • G
    Gregory KimAug 31, 2025
    Goodman AMES800603A Furnace flashes 11 times, what does it mean?
    • K
      Kevin DiazSep 1, 2025
      If your Goodman furnace is not operating and the integrated control module diagnostic LED is flashing eleven times, check and correct the wiring from the integrated control module to the igniter. Replace the igniter if it is bad. Also, check and correct the unit ground wire. This issue may arise from an improperly connected igniter, a bad igniter, or a poor unit ground, or a poor burner ground.
  • H
    Hannah ShahSep 4, 2025
    Goodman Furnace flashes 12 times, what should I do?
    • R
      Ryan JonesSep 4, 2025
      If your Goodman furnace is not operating and the integrated control module diagnostic LED is flashing twelve times, check and correct the wiring from the integrated control module to the inducer. Also, check for any blockage in the inducer and in the vent, and replace the inducer if necessary. Check and correct the unit ground wire. If the problem persists, replace the integrated control module. The cause may be improperly connected inducer, a bad inducer, a poor unit ground, or a faulty integrated control module.
  • N
    Nichole WilliamsSep 8, 2025
    How to fix Goodman AMES800603A Furnace LED flashing continuously?
    • M
      Michael FerrellSep 8, 2025
      If your Goodman furnace fails to operate and the integrated control module diagnostic LED is flashing continuously, review the wiring diagram to correct the polarity. Reverse the orange and gray wires going to the transformer. Verify proper ground. This issue arises when the polarity of the 115 or 24 volt power is reversed.

Summary

Important Information and General Safety

General Notices and Warnings

Important notices, safety warnings on devices, combustible materials, and high voltage.

Carbon Monoxide and Fire Hazard Warnings

Gas Safety and Explosion Risks

Instructions for smelling gas and warnings about fire/explosion.

Carbon Monoxide Poisoning Hazard

Detailed hazard information regarding carbon monoxide poisoning.

Abnormal Heating Operation

System Safety and Product Application

Electrical Safety and ESD Precautions

Warnings on electrical shock, static discharge, and product application.

Servicing - Electrical Checks

Servicing - Airflow and Motors

Servicing - Controls

Servicing - Gas System

Servicing - Ignition System

Servicing - Pressure Switch

Servicing - Control Boards

Troubleshooting Guide

No Heat or Diagnostic Signal Faults

Diagnosing furnace failures when there is no heat or the diagnostic LED is off.

Ignition and Flame Sensing Faults

Troubleshooting ignition retries, flame loss, and flame sensor issues.

Blower, Pressure Switch, and Wiring Issues

Addressing issues with the induced draft blower, pressure switches, and wiring.

Other Operational Faults and Error Codes

Diagnosing continuous blower operation, rollout limits, and twinning faults.

Goodman AMES800603A Specifications

General IconGeneral
ModelAMES800603A
TypeGas Furnace
Heating Capacity80, 000 BTU/h
AFUE Rating80%
Blower MotorMulti-Speed
Fuel TypeNatural Gas
Installation TypeUpflow/Horizontal
BTU Input80, 000 BTU/h
BTU Output64, 000 BTU/h
StagesSingle Stage
BrandGoodman
Input BTU/h80, 000
Output BTU/h64, 000
Voltage115V
Gas TypeNatural Gas
Ignition TypeElectronic Ignition
Heat Exchanger MaterialAluminized Steel
Vent Diameter4 inches
Warranty10 Years Limited Warranty