EasyManua.ls Logo

Goodman Amana AMES80 U Series - User Manual

Goodman Amana AMES80 U Series
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Service and Troubleshooting


Copyright © 2019-2020 Goodman Manufacturing Company, L.P.
RS6621006r2
June 2020
TABLE OF CONTENTS
IMPORTANT INFORMATION ............................................. 2
PRODUCT IDENTIFICATION ............................................ 4
SYSTEM OPERATION ....................................................... 6
SCHEDULED MAINTENANCE ........................................ 12
SERVICING ...................................................................... 15
CHECKING VOLTAGE ...............................................16
CHECKING WIRING ...................................................16
CHECKNG THERMOSTAT, WIRING .........................16
CHECKING TRANSFORMER AND CONTROL
CIRCUIT ....................................................................... 16
CHECKING AIR CIRCULATOR BLOWER MOTOR .17
CHECKING DUCT STATIC ......................................... 17
CHECKING TEMPERATURE RISE ...........................18
CHECKING PRIMARY LIMIT CONTROL ..................18
CHECKING AUXILIARY LIMIT CONTROL ................19
INDUCED DRAFT BLOWER MOTOR .......................19
CECKING GAS VALVE (REDUNDANT) ....................19
CHECKING GAS PRESSURE ...................................20
CHECKING HOT SURFACE IGNITER ......................22
CHECKING PRESSURE TRANSDUCER .................22
CHECKING FOR DELAYED IGNITION ..................... 22
CHECKING INTERGRATED IGNITION CONTROL
BOARDS ......................................................................22
CHECKING FLAME SENSOR ....................................23
TROUBLESHOOTING CHART ........................................ 24
WIRING DIAGRAMS ........................................................ 27
Pride and workmanship go into every product to provide
our customers with quality products. It is possible, however,
that during its lifetime a product may require service.
Products should be serviced only by a qualied service
technician who is familiar with the safety procedures
required in the repair and who is equipped with the proper
tools, parts, testing instruments and the appropriate service
manual. 





















Cancer and Reproductive Harm -
www.P65Warnings.ca.gov
0140M00517-A
Question and Answer IconNeed help?

Do you have a question about the Goodman Amana AMES80 U Series and is the answer not in the manual?

Goodman Amana AMES80 U Series Specifications

General IconGeneral
BrandGoodman
ModelAmana AMES80 U Series
CategoryFurnace
LanguageEnglish

Summary

IMPORTANT INFORMATION

Safety Warnings and Precautions

Essential safety precautions for installation, operation, and potential hazards like carbon monoxide.

PRODUCT IDENTIFICATION

Furnace Model Nomenclature

Explains how to interpret model numbers for identification of furnace components and features.

SYSTEM OPERATION

Operational Safety and Precautions

Outlines critical safety measures and specific warnings related to furnace operation and application.

Operating Modes and Sequences

Details the step-by-step operational sequences for heating, cooling, and fan-only modes.

ID Plugs for Model Configuration

Explains the function and installation of unique ID plugs for specific furnace models.

SCHEDULED MAINTENANCE

Annual Inspection and Component Checks

Procedures for annual inspection of furnace components to ensure proper working order and safety.

Gas Input and Performance Testing

Method for testing gas input by clocking the gas meter and calculating BTU per hour.

SERVICING

Component Identification

Visual identification and labeling of major furnace components for servicing purposes.

Electrical System Checks

Procedures for testing voltage, wiring, thermostat, transformer, and control circuits.

Blower and Airflow Diagnostics

Steps to check the circulator blower motor operation and measure duct static pressure.

Temperature Rise and Limit Control Checks

Procedures for verifying temperature rise and testing primary limit controls.

Gas Pressure Measurement

Procedures for measuring inlet gas supply pressure.

Ignition and Control System Diagnostics

Procedures for testing igniters, pressure transducers, control boards, and delayed ignition.

TROUBLESHOOTING

Diagnostic LED Error Code Interpretation

Diagnosing furnace faults based on LED status codes and providing corrective actions.

Fault Code Management Procedures

Instructions for retrieving and erasing stored fault code history from the control module.

WIRING DIAGRAMS

Related product manuals