Service and Troubleshooting
*MVS96*U

Copyright © 2020 Goodman Manufacturing Company, L.P.
RS6612018r1
June 2020
TABLE OF CONTENTS
IMPORTANT INFORMATION ............................................ 2
PRODUCT IDENTIFICATION ........................................... 4
SYSTEM OPERATION ...................................................... 6
SCHEDULED MAINTENANCE ....................................... 21
SERVICING ..................................................................... 24
CHECKING VOLTAGE .............................................. 25
CHECKING WIRING .................................................. 25
CHECKNG THERMOSTAT, WIRING ........................ 25
CHECKING TRANSFORMER AND CONTROL
CIRCUIT ...................................................................... 25
CHECKING AIR CIRCULATOR BLOWER MOTOR 26
CHECKING DUCT STATIC ........................................ 26
CHECKING TEMPERATURE RISE .......................... 26
CHECKING PRIMARY LIMIT CONTROL ................. 27
CHECKING AUXILIARY LIMIT CONTROL ............... 27
INDUCED DRAFT BLOWER MOTOR ...................... 28
CECKING GAS VALVE (REDUNDANT) ................... 28
CHECKING GAS PRESSURE .................................. 28
CHECKING HOT SURFACE IGNITER ..................... 30
CHECKING PRESSURE TRANSDUCER ................ 30
CHECKING FOR DELAYED IGNITION .................... 31
CHECKING INTERGRATED IGNITION CONTROL
BOARDS ..................................................................... 31
CHECKING FLAME SENSOR ................................... 31
TROUBLESHOOTING CHART ....................................... 32
WIRING DIAGRAMS ....................................................... 39
Pride and workmanship go into every product to provide
our customers with quality products. It is possible, however,
that during its lifetime a product may require service.
Products should be serviced only by a qualied service
technician who is familiar with the safety procedures
required in the repair and who is equipped with the proper
tools, parts, testing instruments and the appropriate service
manual. 





















Cancer and Reproductive Harm -
www.P65Warnings.ca.gov
0140M00517-A

Questions and Answers

  • D
    drakevalerieAug 19, 2025
    What to do if my Goodman furnace fails to operate due to excessive ignition retries?
    • S
      Stephanie HallAug 19, 2025
      If your Goodman furnace fails to operate because of too many ignition retries, the possible causes are failure to establish flame, loss of flame after establishment, or gas interruption. You should locate and correct any gas interruption. Check the front cover pressure switch operation and ensure proper drainage, correcting if necessary. Consider replacing or realigning the igniter. Inspect the flame sense signal, cleaning the sensor if it's coated or oxidized. Verify the flue piping is free from blockages, has the correct length and elbows, and is properly terminated. Also, ensure the induced draft blower is performing as expected.
  • A
    Austin ChapmanAug 21, 2025
    What to do if my Goodman AMVS96U airflow is less than expected?
    • D
      Dana BarkerAug 21, 2025
      If your Goodman furnace's airflow is less than expected, it might be operating in a power, temperature, or speed limiting condition. First, check the filters for any blockage and clean them or remove any obstructions. Next, inspect the ductwork for blockages and make sure all registers are fully open. Finally, verify that the ductwork is appropriately sized for the system; if not, resize or replace it as necessary.
  • R
    Robert BennettAug 23, 2025
    Why my Goodman furnace fails to operate and the integrated control module LED display provides no signal?
    • P
      Patrick GarciaAug 25, 2025
      If your Goodman furnace isn't working and the integrated control module LED display shows no signal, it could be due to a lack of 115V power to the furnace, no 24V power to the integrated control module, a blown fuse, a tripped circuit breaker, or a non-functional integrated control module. Restore high voltage power to the furnace and integrated control module. Replace the integrated control module if it's non-functional.
  • T
    traceyturnerAug 26, 2025
    What to do if my Goodman AMVS96U fails to operate because of grounding fault?
    • D
      David PayneAug 26, 2025
      If your Goodman furnace fails to operate due to a grounding fault or poor neutral connection, verify the neutral wire connection to the furnace and confirm continuity to the ground source.
  • J
    Joann CookAug 28, 2025
    What to do if my Goodman AMVS96U Furnace fails to operate because of an open roll out switch?
    • K
      Kelly OneillAug 28, 2025
      If your Goodman furnace fails to operate due to an open roll out switch, check for correct gas pressure, correct burner alignment, and check for and correct any burner restrictions.
  • M
    Meagan CaseAug 30, 2025
    What to do if my Goodman AMVS96U fails to operate and the circulator blower motor is not running?
    • D
      Danielle WilliamsAug 30, 2025
      If your Goodman furnace fails to operate because the circulator blower motor isn't running when it should be, check the wiring connections to ensure they are tight and correct. Verify there's a continuous circuit through the inductor, and replace it if it's open or short-circuited. Also, inspect the circulator blower motor itself and replace it if necessary.
  • N
    Nancy YoungSep 1, 2025
    What to do if my Goodman AMVS96U fails to operate because of aux limit switch open?
    • R
      Randall MillerSep 1, 2025
      If your Goodman furnace fails to operate because the aux limit switch is open in the blower compartment, check the filters and ductwork for blockages. Clean the filters or remove any obstructions. Also, check the circulator blower speed and performance, correcting the speed or replacing the blower motor if necessary. Ensure that the wiring connections are tight and correct.
  • K
    Kristin UnderwoodSep 5, 2025
    What to do if my Goodman AMVS96U Furnace fails to operate because of a low stage pressure switch issue?
    • J
      Jamie CraigSep 5, 2025
      If your Goodman furnace fails to operate and it's due to the low stage pressure switch circuit being closed at the start of the heating cycle, the low stage pressure switch contacts sticking, or a short in the pressure switch circuit wiring, you should replace the low stage pressure switch or repair the short in the wiring.
  • A
    Angela CastanedaSep 7, 2025
    What to do if my Goodman AMVS96U Furnace operation is different than expected because of invalid memory card data?
    • J
      Joy PhillipsSep 8, 2025
      If your Goodman furnace operation is different than expected due to invalid memory card data, verify the shared data set is correct for the specific model and re-populate the data using the correct memory card if required.
  • B
    Bryce AllenSep 9, 2025
    What to do if my Goodman AMVS96U Furnace fails to operate due to circulator blower motor communication loss?
    • F
      Felicia GarciaSep 10, 2025
      If your Goodman furnace fails to operate because the integrated control module has lost communication with the circulator blower motor, tighten or correct the wiring connections. Check the circulator blower motor and replace if necessary. Also, check the integrated control module and replace it if needed.

Summary

Important Information

Safety Advisories and Warnings

General safety, notices, and specific hazards related to furnace operation and installation.

Carbon Monoxide Hazard

Details risks, precautions, and multilingual warnings regarding carbon monoxide poisoning.

Product Identification

Nomenclature and Model Breakdown

Explains the furnace model number structure, component labels, and specifications.

System Operation

Safety and Operating Warnings

General safety, ESD precautions, product application, and EMI filter guidelines.

Condensate Drainage Systems

Covers drain lines, traps, and horizontal installation requirements for condensate.

Gas Supply and Piping

Details combustion air intake, gas supply, piping checks, and high altitude derate.

Thermostat and Control Logic

Explains thermostat wiring, control system, and comfort setting options.

Airflow and Blower Control

Covers blower speed settings, airflow profiles, and low voltage wiring.

System Wiring and Configurations

Describes control boards, unit types, heat pump, dehumidification, and fossil fuel integration.

User Interface and Connectivity

Details EAC, Aux alarm, CoolCloud App, phone app, push buttons, status menu, and navigation.

Operational Settings and Sequences

Covers fault display, various configuration menus, and normal heating/cooling modes.

Scheduled Maintenance

Annual Inspection Procedures

Procedures for annual checks of flue, heat exchanger, burners, wiring, and filters.

Blower Motor and Flame Sensor Service

Maintenance instructions for blower motors and flame sensors.

Heating Performance Testing

Steps for testing heating system performance, airflow, and temperature rise.

Servicing

Component Identification

Visual guide to the furnace's major components and their locations.

Electrical System Checks

Procedures for testing voltage, thermostat wiring, transformer, and control circuits.

Blower and Duct Static Pressure Checks

Testing the circulator blower motor and measuring duct static pressure.

Temperature Rise and Limit Controls

Measuring air temperature rise and testing primary/auxiliary limit controls.

Gas Valve and Pressure Measurements

Procedures for checking gas valve, inlet, and manifold pressures.

Igniter and Transducer Diagnostics

Steps for testing hot surface igniters and pressure transducers.

Ignition Control and Flame Sensor Testing

Checking delayed ignition, ignition control boards, and flame sensor readings.

Troubleshooting

LED Status Codes and Menu Navigation

Explanation of LED status codes and how to navigate system menus.

Furnace Operation Fault Diagnosis

Common symptoms, fault codes, and corrective actions for general operation issues.

Airflow and Pressure Faults

Details faults related to airflow, pressure sensors, and blocked vents.

Ignition and Gas System Faults

Covers faults related to ignition, gas valve, and limit switches.

Fault Code Recall and Management

Explains how to recall, interpret, and clear fault histories.

Wiring Diagrams

Electrical Schematics and Color Codes

Provides detailed wiring diagrams, connection points, and wire color coding.

Goodman AMVS96U Specifications

General IconGeneral
Fuel TypeNatural Gas or Propane
AFUE96%
Blower MotorVariable Speed
Cabinet TypeUpflow/Horizontal
Heating Capacity40, 000 to 120, 000 BTU/h
Heat ExchangerStainless Steel
Stages2
WarrantyLimited Lifetime Warranty on Heat Exchanger, 10-Year Parts Warranty