Service and Troubleshooting


Copyright © 2021 Goodman Manufacturing Company, L.P.
RS6621008
July 2021
TABLE OF CONTENTS
IMPORTANT INFORMATION ............................................ 2
PRODUCT IDENTIFICATION ........................................... 4
SYSTEM OPERATION ...................................................... 5
SCHEDULED MAINTENANCE ....................................... 25
SERVICING ..................................................................... 29
CHECKING VOLTAGE .............................................. 30
CHECKING WIRING .................................................. 30
CHECKING THERMOSTAT, WIRING ....................... 30
CHECKING TRANSFORMER AND CONTROL
CIRCUIT ...................................................................... 31
CHECKING AIR CIRCULATOR BLOWER MOTOR 31
CHECKING DUCT STATIC ........................................ 32
CHECKING TEMPERATURE RISE .......................... 32
CHECKING PRIMARY LIMIT CONTROL ................. 33
CHECKING AUXILIARY LIMIT CONTROL ............... 33
CHECKING FLAME ROLLOUT CONTROL ............. 34
INDUCED DRAFT BLOWER MOTOR ...................... 35
CHECKING GAS VALVE (REDUNDANT) ................ 35
CHECKING MAIN BURNERS ................................... 35
CHECKING ORIFICES .............................................. 35
CHECKING GAS PRESSURE .................................. 36
CHECKING HOT SURFACE IGNITER ..................... 38
CHECKING FOR FLASHBACK ................................. 38
CHECKING PRESSURE SWITCH............................ 38
HIGH ALTITUDE APPLICATION ............................... 39
CHECKING FOR DELAYED IGNITION .................... 39
CHECKING INTEGRATED IGNITION CONTROL
BOARDS ..................................................................... 40
CHECKING FLAME SENSOR ................................... 40
AIRFLOW TABLES ........................................................ 42
1 STAGE STATUS CODES ........................................... 50
1 STAGE TROUBLESHOOTING CODES.................... 52
WIRING DIAGRAMS ....................................................... 54
Pride and workmanship go into every product to provide
our customers with quality products. It is possible, however,
that during its lifetime a product may require service.

technician who is familiar with the safety procedures
required in the repair and who is equipped with the proper
tools, parts, testing instruments and the appropriate service
manual. 







-
-










Questions and Answers

  • T
    Tammy NavarroAug 18, 2025
    What to do if my Goodman AM9S80 Furnace fails to operate due to furnace lockout?
    • J
      jjacksonAug 18, 2025
      If your Goodman Furnace fails to operate due to a furnace lockout caused by an excessive number of ignition retries, failure to establish flame, or loss of flame after establishment, you should locate and correct the gas interruption.
  • D
    devingilesAug 20, 2025
    What to do if my Goodman AM9S80 Furnace is not working?
    • E
      Elizabeth WilliamsAug 20, 2025
      If your Goodman Furnace is not working, it could be due to an open fuse or a short in the low voltage wiring. Replace the fuse or locate and correct the short in the low voltage wiring.
  • C
    Christine MataAug 23, 2025
    What to do if my Goodman AM9S80 isn't working, and the integrated control module LED display provides no signal?
    • R
      Ronnie DavisAug 25, 2025
      If your Goodman Furnace fails to operate and the integrated control module LED display provides no signal, it may be due to no 115 power to furnace or no 24 volt power to integrated control module, a blown fuse, a tripped circuit breaker, or a non-functional integrated control module. Restore high voltage power to furnace and integrated control module. Correct the condition which caused the fuse to open, replace the fuse.
  • J
    Jaime BrownAug 26, 2025
    Why is my Goodman AM9S80 failing to operate?
    • M
      Matthew LiuAug 26, 2025
      Your Goodman Furnace may fail to operate due to a problem with the igniter circuit, an improperly connected or shorted igniter, a poor unit ground, or an igniter relay fault on the integrated control module. Check and correct the wiring from the integrated control module to the igniter.
  • T
    Timothy BarnesAug 28, 2025
    What to do if my Goodman AM9S80 fails to operate due to an open roll out switch?
    • T
      tammie29Aug 28, 2025
      If your Goodman Furnace fails to operate due to an open roll out switch, check for correct gas pressure.
  • P
    Philip LoweAug 30, 2025
    Why is my Goodman AM9S80 Furnace induced draft blower and circulator blower running continuously?
    • G
      garciajenniferAug 31, 2025
      If the induced draft blower and circulator blower run continuously with no furnace operation, it may be due to flame sensed with no call for heat, a short to ground in the flame sense circuit, a lingering burner flame, or a slow closing gas valve. Correct the short at the flame sensor or in the flame sensor wiring and verify proper operation of gas valve.
  • R
    rileyallisonSep 2, 2025
    What to do if my Goodman AM9S80 isn't working and has a grounding fault?
    • W
      wileyjasonSep 2, 2025
      If your Goodman Furnace fails to operate due to a grounding fault or poor neutral connection, verify the neutral wire connection to the furnace and its continuity to the ground source.
  • J
    jasonjacksonSep 4, 2025
    What to do if my Goodman AM9S80 fails to operate due to Ignitor Open?
    • J
      jonathan39Sep 4, 2025
      If your Goodman Furnace fails to operate due to an open ignitor, check the ignitor wiring and replace the damaged ignitor.
  • J
    Jennifer WareSep 7, 2025
    What to do if my Goodman AM9S80 Furnace fails to operate due to Inducer relay Error?
    • S
      Sheila DelgadoSep 7, 2025
      If your Goodman Furnace fails to operate due to an inducer relay error, replace the integrated control board.
  • W
    wayneescobarSep 10, 2025
    What to do if my Goodman AM9S80 Furnace fails to operate due to Pressure switch circuit?
    • B
      Brian BaileySep 10, 2025
      If your Goodman Furnace fails to operate due to a pressure switch circuit that is closed at the start of the heating cycle, pressure switch contacts sticking, or a short in the pressure switch circuit wiring, replace the low stage pressure switch and repair the short in wiring.

Summary

Service and Troubleshooting

IMPORTANT INFORMATION

General notices about safety and service, including symbols and warnings.

CARBON MONOXIDE POISONING HAZARD

Critical safety information regarding carbon monoxide dangers.

SYSTEM OPERATION

Details on furnace operation, sequences, and electrical connections.

FURNACE STARTUP

Step-by-step guide for safely starting the furnace.

SAFETY

Comprehensive warnings and cautions for installation and operation.

LOCATION REQUIREMENTS AND CONSIDERATIONS

Guidelines for selecting an appropriate installation location.

COMBUSTION AND VENTILATION AIR REQUIREMENTS

Critical information on air supply needed for safe operation.

CATEGORY I VENTING (VERTICAL VENTING)

Specific requirements for venting 80% furnaces.

MASONRY CHIMNEYS

Guidelines for venting through masonry chimneys.

PROPANE GAS AND;OR HIGH ALTITUDE INSTALLATIONS

Instructions for converting to propane or installing at high altitudes.

GAS SUPPLY AND PIPING

Guidelines for connecting the gas supply and piping.

SCHEDULED MAINTENANCE

ANNUAL INSPECTION

Recommended annual checks for furnace components and safety.

SERVICING

CHECKING GAS PRESSURE

Procedure for measuring and verifying gas supply pressure.

GAS MANIFOLD PRESSURE MEASUREMENT AND ADJUSTMENT

Measuring and adjusting manifold gas pressure for optimal combustion.

1 STAGE TROUBLESHOOTING CODES

WIRING DIAGRAMS

Goodman AM9S80 Specifications

General IconGeneral
ModelAM9S80
Heating Capacity40, 000-120, 000 BTU/h
Warranty10-Year Parts Limited Warranty, Lifetime Heat Exchanger Limited Warranty
StagesSingle-Stage
ConfigurationUpflow/Horizontal
Efficiency80% AFUE
Fuel TypeNatural Gas
Blower Motor TypeVariable Speed