Service and Troubleshooting


Copyright © 2019-2020 Goodman Manufacturing Company, L.P.
This manual is to be used by qualied, professionally
trained HVAC technicians only. Goodman does not assume
any responsibility for property damage or personal injury
due to improper service procedures or services performed
by an unqualied person.
RS6621003r3
April 2020
®
is a registered trademark of Maytag Corporation or its related companies and is used under license.
All rights reserved.
TABLE OF CONTENTS
IMPORTANT INFORMATION ............................................ 2
PRODUCT IDENTIFICATION ........................................... 4
SYSTEM OPERATION ...................................................... 6
SCHEDULED MAINTENANCE ....................................... 25
SERVICING ..................................................................... 27
ACESSORIES ................................................................. 45
TROUBLESHOOTING CHART ....................................... 48
WIRING DIAGRAMS ....................................................... 51
Pride and workmanship go into every product to provide
our customers with quality products. It is possible, however,
that during its lifetime a product may require service.
Products should be serviced only by a qualied service
technician who is familiar with the safety procedures
required in the repair and who is equipped with the proper
tools, parts, testing instruments and the appropriate service
manual. 




















Cancer and Reproductive Harm -
www.P65Warnings.ca.gov
0140M00517-A

Questions and Answers

  • A
    Alejandra WilliamsAug 13, 2025
    What to do if Goodman AMES800603B LED is flashing 1 time?
    • W
      William AlvarezAug 14, 2025
      If your Goodman Furnace fails to operate and the integrated control module diagnostic LED is flashing once, it indicates a furnace lockout due to excessive ignition retries. This can be caused by a gas interruption. You should locate and correct the gas interruption. Also check the front cover pressure switch operation, including the hose, wiring, and contact operation, and correct if necessary. Other possible solutions include replacing or realigning the igniter, checking the flame sense signal (sanding the sensor if coated or oxidized), checking the flue piping for blockage, proper length, elbows, and termination, and verifying proper induced draft blower performance.
  • W
    williamcombsAug 17, 2025
    How to troubleshoot Goodman AMES800603B Furnace with no LED signal?
    • M
      Megan GrayAug 17, 2025
      If your Goodman furnace fails to operate and the integrated control module diagnostic LED provides no signal, ensure that there is 115 and 24 volt power to the furnace integrated control module. Check the integrated control module fuse (3A) and replace it if necessary. Check for possible shorts in the 115 and 24 volt circuits and repair as needed. A faulty integrated control module may also be the cause, so replace it if necessary. The cause may be a manual disconnect switch being OFF, door switch open, or 24 volt wires improperly connected or loose, or a blown fuse or circuit breaker.
  • G
    George HardyAug 21, 2025
    What does 6 flashes mean on a Goodman AMES800603B Furnace?
    • A
      Adrienne LynchAug 21, 2025
      If your Goodman furnace fails to operate and the integrated control module diagnostic LED is flashing six times, it could be due to flame rollout. Check the burners for proper alignment. Also, check the flue and air inlet piping for blockage, proper length, elbows, and termination, and correct as necessary. Check the rollout limit and replace it if necessary. Ensure the induced draft blower is performing properly, and replace it if necessary. The problem may also be due to misaligned burners, a blocked flue and/or air inlet pipe, or a failed induced draft blower. Check and correct any loose or improperly connected wiring. A short in the 24 volt AC control circuits or safety circuits, or a faulty rollout limit can also cause this issue. Tighten or correct any wiring connections.
  • C
    Cynthia HorneAug 25, 2025
    Goodman AMES800603B Furnace flashes 8 times, what does it mean?
    • D
      Danielle SpearsAug 25, 2025
      If your Goodman furnace is not operating and the integrated control module diagnostic LED is flashing eight times, check and correct the wiring from the integrated control module to the igniter. Replace the igniter if it is bad. Check and correct the unit ground wire. If the issue persists, replace the integrated control module. This may be caused by an improperly connected igniter, a bad igniter, a poor unit ground, a poor burner ground, or a faulty integrated control module.
  • J
    Jessica MarksAug 29, 2025
    What does 2 flashes mean on a Goodman AMES800603B Furnace?
    • F
      fstephensAug 29, 2025
      If your Goodman furnace fails to operate and the integrated control module diagnostic LED is flashing twice, it could be due to induced draft blower pressure switch contacts sticking. In this case, replace the induced draft blower pressure switch. It could also be caused by shorts in the pressure switch circuit, which would require repairing the short.
  • D
    David AllisonSep 1, 2025
    Goodman Furnace flashes 11 times, what does it mean?
    • C
      cromeroSep 1, 2025
      If your Goodman furnace is not operating and the integrated control module diagnostic LED is flashing eleven times, check and correct the wiring from the integrated control module to the igniter. Replace the igniter if it is bad. Also, check and correct the unit ground wire. This issue may arise from an improperly connected igniter, a bad igniter, or a poor unit ground, or a poor burner ground.
  • C
    Cody WilliamsonSep 5, 2025
    Goodman AMES800603B flashes 12 times, what should I do?
    • M
      Michael EdwardsSep 5, 2025
      If your Goodman furnace is not operating and the integrated control module diagnostic LED is flashing twelve times, check and correct the wiring from the integrated control module to the inducer. Also, check for any blockage in the inducer and in the vent, and replace the inducer if necessary. Check and correct the unit ground wire. If the problem persists, replace the integrated control module. The cause may be improperly connected inducer, a bad inducer, a poor unit ground, or a faulty integrated control module.
  • J
    Jennifer RyanSep 8, 2025
    How to fix Goodman Furnace LED flashing continuously?
    • W
      William HillSep 9, 2025
      If your Goodman furnace fails to operate and the integrated control module diagnostic LED is flashing continuously, review the wiring diagram to correct the polarity. Reverse the orange and gray wires going to the transformer. Verify proper ground. This issue arises when the polarity of the 115 or 24 volt power is reversed.

Summary

Important Information and Safety

System Operation Details

Heating - Abnormal Operation

Lists probable causes and fixes for abnormal heating operation based on LED diagnostic codes.

Servicing and Diagnostics

Checking Voltage and Wiring

Step-by-step guide to checking voltage and inspecting furnace wiring.

Integrated Ignition Control and Troubleshooting

Detailed tests for the integrated ignition control module and common fault codes.

Troubleshooting Guide by LED Code

Troubleshooting - No Signal & Steady On LED

Troubleshooting steps when the diagnostic LED shows no signal or is steady on.

Troubleshooting - Ignition & Flame Issues (1-8 Flashes)

Diagnosing ignition retries, flame loss, rollout, flame sense, and igniter faults indicated by LED flashes.

Troubleshooting - Blower & Control Issues (3-5, 12 Flashes)

Addressing blower operation, inducer relay faults, and control module issues indicated by LED flashes.

Troubleshooting - Power & Polarity Issues (10, 11, Continuous Flash)

Diagnosing issues related to power supply, polarity, fuses, and igniter problems indicated by LED flashes.

Goodman AMES800603B Specifications

General IconGeneral
BrandGoodman
Model NumberAMES800603B
TypeGas Furnace
Input BTU60, 000
Output BTU48, 000
Efficiency80%
Blower MotorMulti-Speed
Fuel TypeNatural Gas
StagesSingle Stage
Ignition TypeElectronic
Heat Exchanger Warranty20-Year
Unit Warranty10 Years