PRODUCT IDENTIFICATION
4

The model and manufacturing number are used for positive identication of component parts used in manufacturing.
Please use these numbers when requesting service or parts information.
G M E S 8 0 0 6 0 3 A N A A
1 2 3 4 5 6 7 8 9 10 11 12 13
Brand Minor Revision
G - Goodman® A - Inial Release
V - GM B - 1st Revision
Conguraon
M - Upow/Horizontal Major Revision
C - Counterflow/Horizontal A - Inial Release
B - 1st Revision
S - PSC Motor Nox
E - Constant Torque Motor/Mul-Speed ECM N - Natural Gas
V - Variable Speed ECM X - Low NOx
U - Ultra-Low NOx
Gas Vale / Motor
S - Single Stage / Single Speed Cabinet Width
A - 14"
B - 17.5"
AFUE C - 21"
80 - 80% A
FUE D - 24.5"
Maximum CFM
MBTU/h 3 - 1200 CFM
40 - 40,000 4 - 1600 CFM
60 - 60,000 5 - 2000 CFM
80 - 80,000
100 - 100,000
120 - 120,000
Goodman Furnace Nomenclature (13 Digits)