BLOWER PERFORMANCE DATA
20
ARUF
Note: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208V/240V)
0.1" 0.2" 0.3" 0.4" 0.5"
High 1155 1090 1025 950 895
ARUF172916 Med. 940 890 860 815 755
Low 695 665 650 610 550
High 1155 1090 1025 950 895
ARUF182416 Med. 940 890 860 815 755
Low 695 665 650 610 550
High 1135 1085 1025 965 915
ARUF193116 Med. 860 825 780 750 680
Low
600 570 545 500 465
High 1385 1315 1240 1155 1065
ARUF303016 Med. 1340 1290 1230 1140 1050
Low 1075 1030 980 910 840
High 1310 1240 1155 1090 1020
ARUF363616 Med.
1270 1210 1140 1075 980
Low
1045 1005 955 885 805
High 1700 1660 1625 1545 1505
ARUF364216 Med. 1500 1440 1400
1350 1345
Low 1330 1300 1250
1230 1220
High 2065 2000 1925 1860 1780
ARUF374316
Med. 1685 1635 1550 1470 1410
Low 1490 1425 1345 1280 1205
High 2150 2120 2070 2000 1940
ARUF486016
Med. 1940 1930 1905 1860 1790
Low 1610 1600 1590 1575 1550
High 2150 2105 2040 1970 1880
ARUF496116 Med. 1960 1935 1895 1825 1750
Low 1670 1625 1585 1525 1455
CFM deliverd against External Static Pressure